Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
381
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0284 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $52,170 | $49,000 | Not Implemented |
OK0746 # 12 Y:2007 | 12 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $24,000 | $840,000 | Not Implemented |
OK0746 # 11 Y:2007 | 11 | 2007 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $30,387 | $15,000 | Not Implemented |
OK0746 # 10 Y:2007 | 10 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $40,383 | $400 | Not Implemented |
OK0746 # 09 Y:2007 | 09 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $49,382 | $46,200 | Not Implemented |
OK0746 # 08 Y:2007 | 08 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $39,725 | $63,500 | Not Implemented |
OK0746 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,881 | $0 | Implemented |
OK0746 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,881 | $3,256 | Implemented |
OK0746 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,287 | $3,000 | Implemented |
OK0746 # 04 Y:2007 | 04 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,580 | $4,541 | Implemented |
OK0746 # 03 Y:2007 | 03 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $52,302 | $14,800 | Not Implemented |
OK0746 # 02 Y:2007 | 02 | 2007 | USE SOLAR HEAT FOR HEAT | $26,050 | $140,000 | Not Implemented |
OK0746 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $32,026 | $30,757 | Implemented |
OK0726 # 11 Y:2006 | 11 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,188 | $5,750 | Not Implemented |
OK0726 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $1,213 | $331 | Not Implemented |
OK0726 # 09 Y:2006 | 09 | 2006 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $579 | $2,006 | Not Implemented |
OK0726 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,168 | $8,723 | Not Implemented |
OK0726 # 07 Y:2006 | 07 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $55,348 | $35,269 | Not Implemented |
OK0726 # 06 Y:2006 | 06 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $31,992 | $32,500 | Not Implemented |
OK0726 # 05 Y:2006 | 05 | 2006 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $18,769 | $16,500 | Not Implemented |
OK0726 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,283 | $32,000 | Not Implemented |
OK0726 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $2,127 | $339 | Not Implemented |
OK0726 # 02 Y:2006 | 02 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,412 | $13,554 | Not Implemented |
OK0726 # 01 Y:2006 | 01 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,838 | $2,305 | Not Implemented |
OK0725 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,367 | $27,265 | Not Implemented |