Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,647
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0283 # 03 Y:2004 | 03 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,636 | $829 | Implemented |
SF0283 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,377 | $31,490 | Implemented |
SF0283 # 05 Y:2004 | 05 | 2004 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $61,990 | $40,000 | Implemented |
SF0283 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,808 | $20,000 | Not Implemented |
SF0283 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $1,284 | $1,218 | Implemented |
SF0283 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,669 | $10,828 | Implemented |
SF0283 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $1,066 | $2,688 | Implemented |
SF0283 # 10 Y:2004 | 10 | 2004 | USE AN AUTOMATIC PLATE PROCESSOR | $27,300 | $40,500 | Implemented |
SF0283 # 11 Y:2004 | 11 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $227,033 | $40,600 | Not Implemented |
SF0282 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,198 | $0 | Implemented |
SF0282 # 02 Y:2004 | 02 | 2004 | INSTALL STEAM TRAP | $1,304 | $299 | Implemented |
SF0282 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,053 | $2,417 | Implemented |
SF0282 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $2,015 | $1,440 | Not Implemented |
SF0282 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,516 | $14,960 | Not Implemented |
SF0282 # 06 Y:2004 | 06 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $272 | $571 | Not Implemented |
SF0282 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $442 | $1,200 | Implemented |
SF0282 # 08 Y:2004 | 08 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,037 | $5,155 | Not Implemented |
SF0282 # 09 Y:2004 | 09 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,517 | $8,685 | Not Implemented |
SF0282 # 10 Y:2004 | 10 | 2004 | INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE | $34,944 | $72 | Implemented |
SF0282 # 11 Y:2004 | 11 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $20,271 | $21,650 | Not Implemented |
SF0282 # 12 Y:2004 | 12 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,645 | $2,914 | Not Implemented |
SD0336 # 01 Y:2004 | 01 | 2004 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $29,002 | $0 | Implemented |
SD0336 # 02 Y:2004 | 02 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,058 | $46,550 | Not Implemented |
SD0336 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,638 | $6,230 | Implemented |
SD0336 # 04 Y:2004 | 04 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,095 | $0 | Implemented |