Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0506 # 01 Y:2021 | 01 | 2021 | COMBINE UTILITY METERS | $83,765 | $2,853 | Not Implemented |
AS0506 # 02 Y:2021 | 02 | 2021 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $32,780 | $1,503 | Not Implemented |
AS0506 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,228 | $16,466 | Not Implemented |
AS0506 # 04 Y:2021 | 04 | 2021 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $11,446 | $21,173 | Not Implemented |
AS0506 # 05 Y:2021 | 05 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,417 | $27,733 | Not Implemented |
AS0506 # 06 Y:2021 | 06 | 2021 | INSTALL OCCUPANCY SENSORS | $7,913 | $1,399 | Not Implemented |
DL0189 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $5,300 | $425 | Implemented |
DL0189 # 02 Y:2021 | 02 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,750 | $2,550 | Not Implemented |
DL0189 # 03 Y:2021 | 03 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,300 | $3,250 | Not Implemented |
DL0189 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,940 | $20,000 | Implemented |
DL0189 # 05 Y:2021 | 05 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,110 | $72,258 | Implemented |
DL0189 # 06 Y:2021 | 06 | 2021 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,820 | $24,000 | Implemented |
DL0189 # 07 Y:2021 | 07 | 2021 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $24,980 | $15,000 | Not Implemented |
LS2009 # 01 Y:2020 | 01 | 2020 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $209 | $13 | Not Implemented |
LS2009 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,136 | $360 | Implemented |
LS2009 # 03 Y:2020 | 03 | 2020 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $155 | $25 | Not Implemented |
LS2009 # 04 Y:2020 | 04 | 2020 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $71 | $50 | Implemented |
LS2009 # 05 Y:2020 | 05 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $69 | $88 | Implemented |
LS2009 # 06 Y:2020 | 06 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,426 | $2,260 | Implemented |
LS2009 # 07 Y:2020 | 07 | 2020 | INSTALL AUTOMATIC PACKING EQUIPMENT | $57,969 | $120,000 | Implemented |
LS2009 # 08 Y:2020 | 08 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,664 | $14,000 | Not Implemented |
UU0180 # 01 Y:2021 | 01 | 2021 | OPTIMIZE PLANT POWER FACTOR | $12,454 | $25,000 | Not Implemented |
UU0180 # 02 Y:2021 | 02 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,938 | $33,750 | Not Implemented |
UU0180 # 03 Y:2021 | 03 | 2021 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,182 | $4,000 | Implemented |
UU0180 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,073 | $13,873 | Implemented |