Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,647

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0050 # 13 Y:2003 13 2003 INSTALL AUTOMATIC PACKING EQUIPMENT $62,400 $100,000 Not Implemented
LM0050 # 14 Y:2003 14 2003 USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY $101,616 $150,000 Not Implemented
SD0309 # 01 Y:2003 01 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $33,835 $30,000 Not Implemented
SD0309 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,073 $600 Implemented
SD0309 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $5,128 $3,024 Not Implemented
SD0309 # 04 Y:2003 04 2003 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $5,120 $20,000 Not Implemented
SD0309 # 05 Y:2003 05 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,945 $4,000 Not Implemented
SD0309 # 06 Y:2003 06 2003 INSTALL SKYLIGHTS $4,178 $9,500 Not Implemented
SD0309 # 07 Y:2003 07 2003 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,955 $2,263 Implemented
SD0309 # 08 Y:2003 08 2003 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $8,000 $10,000 Implemented
SD0309 # 09 Y:2003 09 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $3,820 $14,000 Not Implemented
SD0309 # 10 Y:2003 10 2003 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $11,200 $2,500 Implemented
SD0308 # 01 Y:2002 01 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $168,158 $56,000 Not Implemented
SD0308 # 02 Y:2002 02 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $7,470 $6,000 Not Implemented
SD0308 # 03 Y:2002 03 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,224 $5,000 Not Implemented
SD0308 # 04 Y:2002 04 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $1,853 $0 Not Implemented
SD0308 # 05 Y:2002 05 2002 USE PHOTOCELL CONTROLS $525 $500 Not Implemented
SD0308 # 06 Y:2002 06 2002 INCREASE USE OF AUTOMATION $91,000 $75,000 Not Implemented
SF0244 # 01 Y:2002 01 2002 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $31,136 $7,960 Not Implemented
SF0244 # 02 Y:2002 02 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $107,810 $50,000 Implemented
SF0244 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $36,936 $19,350 Not Implemented
SF0244 # 04 Y:2002 04 2002 REDUCE FLUID FLOW RATES $31,494 $16,627 Implemented
SF0244 # 05 Y:2002 05 2002 INSTALL OCCUPANCY SENSORS $2,185 $1,200 Not Implemented
SF0244 # 06 Y:2002 06 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,304 $4,110 Implemented
SF0244 # 07 Y:2002 07 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $21,274 $17,580 Implemented