Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0303 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,621 | $9,954 | Implemented |
OK0303 # 03 Y:1990 | 03 | 1990 | IMPROVE LUBRICATION PRACTICES | $20,940 | $0 | Implemented |
OK0303 # 04 Y:1990 | 04 | 1990 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $8,837 | $2,075 | Not Implemented |
OR0076 # 01 Y:1990 | 01 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,574 | $1,000 | Implemented |
OR0076 # 02 Y:1990 | 02 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,005 | $652 | Not Implemented |
OR0076 # 03 Y:1990 | 03 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $655 | $345 | Implemented |
OR0076 # 04 Y:1990 | 04 | 1990 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $658 | $390 | Not Implemented |
OR0076 # 05 Y:1990 | 05 | 1990 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,222 | $3,600 | Not Implemented |
OR0076 # 06 Y:1990 | 06 | 1990 | INSULATE BARE EQUIPMENT | $206 | $333 | Implemented |
OR0076 # 07 Y:1990 | 07 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,585 | $6,190 | Implemented |
OR0076 # 08 Y:1990 | 08 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $434 | $1,118 | Implemented |
OR0076 # 09 Y:1990 | 09 | 1990 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $486 | $1,553 | Not Implemented |
OR0077 # 01 Y:1990 | 01 | 1990 | USE MINIMUM STEAM OPERATING PRESSURE | $1,772 | $0 | Not Implemented |
OR0077 # 02 Y:1990 | 02 | 1990 | INSULATE FEEDWATER TANK | $755 | $297 | Not Implemented |
OR0077 # 03 Y:1990 | 03 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $658 | $478 | Not Implemented |
OR0077 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,589 | $0 | Implemented |
OR0077 # 05 Y:1990 | 05 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $191 | $166 | Not Implemented |
OR0077 # 06 Y:1990 | 06 | 1990 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,471 | $3,766 | Not Implemented |
OR0077 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $491 | $500 | Implemented |
OR0077 # 08 Y:1990 | 08 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,807 | $6,145 | Not Implemented |
OR0077 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $788 | $2,117 | Not Implemented |
CO0170 # 01 Y:1989 | 01 | 1989 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,370 | $3,200 | Not Implemented |
CO0170 # 02 Y:1989 | 02 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $660 | $500 | Not Implemented |
CO0170 # 03 Y:1989 | 03 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,760 | $1,000 | Implemented |
CO0170 # 04 Y:1989 | 04 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,273 | $3,850 | Implemented |