Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,785
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0285 # 08 Y:1989 | 08 | 1989 | RECOVER AND REUSE COOLING WATER | $16,548 | $2,500 | Implemented |
KU0285 # 09 Y:1989 | 09 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,347 | $26,640 | Not Implemented |
KU0285 # 10 Y:1989 | 10 | 1989 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $26,087 | $60,000 | Not Implemented |
KU0285 # 11 Y:1989 | 11 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,539 | $50,000 | Implemented |
KU0287 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,331 | $4,000 | Not Implemented |
KU0287 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,271 | $400 | Implemented |
KU0287 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,214 | $4,800 | Not Implemented |
KU0287 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,735 | $2,700 | Not Implemented |
KU0287 # 05 Y:1989 | 05 | 1989 | INSTALL TURBULATORS | $3,748 | $2,160 | Not Implemented |
MA0153 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $632 | $217 | Not Implemented |
MA0153 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $878 | $163 | Implemented |
MA0153 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,825 | $500 | Implemented |
MA0153 # 04 Y:1989 | 04 | 1989 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $19,722 | $115,000 | Not Implemented |
MA0153 # 05 Y:1989 | 05 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,985 | $1,910 | Not Implemented |
MA0153 # 06 Y:1989 | 06 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $530 | $218 | Not Implemented |
MA0153 # 07 Y:1989 | 07 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,615 | $3,000 | Not Implemented |
TN0373 # 01 Y:1989 | 01 | 1989 | OPERATE BOILERS ON HIGH FIRE SETTING | $11,558 | $20,160 | Implemented |
TN0373 # 02 Y:1989 | 02 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $7,050 | $11,350 | Implemented |
TN0373 # 03 Y:1989 | 03 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $8,465 | $12,145 | Not Implemented |
TN0373 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,164 | $180 | Implemented |
TN0373 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $46 | $0 | Implemented |
TN0373 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,599 | $1,800 | Implemented |
TN0373 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,407 | $540 | Implemented |
CO0153 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,887 | $48 | Implemented |
CO0153 # 02 Y:1989 | 02 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $10,814 | $4,100 | Implemented |