Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

227

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0052 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,928 $245 Implemented
UM0052 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,568 $12,455 Implemented
UM0052 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,290 $500 Implemented
UM0052 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,105 $500 Implemented
UM0052 # 06 Y:1996 06 1996 USE LESS WASTEFUL PACKAGING $817 $0 Not Implemented
UM0052 # 07 Y:1996 07 1996 RECOVER AND REUSE WASTE MATERIAL $4,620 $1,500 Implemented
UM0026 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $215 $305 Implemented
UM0026 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,265 $5,362 Implemented
UM0026 # 03 Y:1995 03 1995 INSTALL AUTOMATIC STACK DAMPER $855 $500 Not Implemented
UM0026 # 04 Y:1995 04 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $443 $451 Not Implemented
UM0016 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $536 $462 Implemented
UM0016 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,210 $15,700 Implemented
UM0016 # 03 Y:1995 03 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,760 $530 Implemented
UM0016 # 04 Y:1995 04 1995 INSTALL TIMERS AND/OR THERMOSTATS $2,530 $460 Implemented
ND0034 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,322 $11,510 Not Implemented
ND0034 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $2,439 $2,439 Not Implemented
ND0034 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,724 $680 Not Implemented
ND0034 # 04 Y:1992 04 1992 REPAIR OR REPLACE STEAM TRAPS $812 $650 Not Implemented
ND0034 # 05 Y:1992 05 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $689 $250 Not Implemented
ND0034 # 06 Y:1992 06 1992 INSULATE BARE EQUIPMENT $667 $324 Not Implemented
ND0034 # 07 Y:1992 07 1992 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $58 $231 Not Implemented
ND0025 # 01 Y:1992 01 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,354 $1,000 Implemented
ND0025 # 02 Y:1992 02 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,815 $8,000 Implemented
ND0025 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,424 $1,584 Not Implemented
ND0025 # 04 Y:1992 04 1992 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,571 $0 Not Implemented