Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0375 # 01 Y:2000 | 01 | 2000 | MINIMIZE WATER USAGE | $13,250 | $3,170 | Implemented |
AM0375 # 09 Y:2000 | 09 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $300 | $0 | Implemented |
AM0375 # 08 Y:2000 | 08 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $500 | $1,060 | Implemented |
AM0375 # 07 Y:2000 | 07 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $835 | $0 | Implemented |
AM0375 # 06 Y:2000 | 06 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,060 | $0 | Not Implemented |
AM0375 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,390 | $720 | Implemented |
AM0375 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,180 | $300 | Implemented |
AM0375 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $5,500 | $10,990 | Implemented |
AM0375 # 02 Y:2000 | 02 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,590 | $500 | Implemented |
TP0015 # 09 Y:2000 | 09 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $334 | $301 | Not Implemented |
TP0015 # 02 Y:2000 | 02 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,404 | $6,200 | Not Implemented |
TP0015 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,255 | $509 | Implemented |
TP0015 # 04 Y:2000 | 04 | 2000 | $1,092 | $0 | Implemented | |
TP0015 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,056 | $0 | Implemented |
TP0015 # 06 Y:2000 | 06 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $566 | $3,147 | Not Implemented |
TP0015 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $152 | $634 | Not Implemented |
TP0015 # 08 Y:2000 | 08 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $455 | $84 | Not Implemented |
TP0015 # 01 Y:2000 | 01 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,906 | $600 | Implemented |
TP0010 # 08 Y:2000 | 08 | 2000 | ADD AREA LIGHTING SWITCHES | $111 | $0 | n/a |
TP0010 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $173 | $267 | n/a |
TP0010 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $428 | $450 | n/a |
TP0010 # 05 Y:2000 | 05 | 2000 | COMBINE UTILITY METERS | $660 | $415 | n/a |
TP0010 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $973 | $874 | n/a |
TP0010 # 03 Y:2000 | 03 | 2000 | USE SYNTHETIC LUBRICANT | $1,314 | $0 | n/a |
TP0010 # 02 Y:2000 | 02 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $10,633 | $2,612 | n/a |