Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

289

matching recommendations
Reset
SIC 20 Food and Kindred Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0294 # 04 Y:2001 04 2001 INSTALL SKYLIGHTS $1,527 $3,086 Not Implemented
AS0294 # 03 Y:2001 03 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,492 $15,000 Implemented
AS0294 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,366 $6,076 Implemented
AS0294 # 01 Y:2001 01 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,268 $2,070 Implemented
UF0289 # 05 Y:2001 05 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,758 $11,274 Implemented
UF0289 # 07 Y:2001 07 2001 $35,100 $4,494 Implemented
UF0289 # 03 Y:2001 03 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $5,004 $6,175 Implemented
UF0289 # 04 Y:2001 04 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $869 $500 Implemented
UF0289 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $2,566 $1,457 Not Implemented
UF0289 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,791 $2,728 Implemented
UF0289 # 06 Y:2001 06 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $389 $1,895 Not Implemented
UF0289 # 08 Y:2001 08 2001 $9,660 $4,612 Implemented
OK0615 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,798 $913 Not Implemented
OK0615 # 07 Y:2001 07 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $536 $163 Implemented
OK0615 # 10 Y:2001 10 2001 REPLACE BOILER $7,761 $22,000 Not Implemented
OK0615 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $1,844 $585 Implemented
OK0615 # 08 Y:2001 08 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $20,688 $8,572 Not Implemented
OK0615 # 05 Y:2001 05 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,147 $238 Not Implemented
OK0615 # 06 Y:2001 06 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,998 $6,000 Not Implemented
OK0615 # 09 Y:2001 09 2001 CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS $13,745 $240 Implemented
OK0615 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,895 $5,476 Implemented
OK0615 # 04 Y:2001 04 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $3,788 $250 Implemented
UF0288 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,662 $6,465 Not Implemented
UF0288 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,358 $500 Implemented
UF0288 # 03 Y:2001 03 2001 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $18,443 $30,000 Not Implemented