IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,939

matching recommendations
Reset
SIC 201 Meat Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LT0097 # 06 Y:1987 06 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,100 $670 Implemented
CO0095 # 01 Y:1987 01 1987 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $84,858 $27,000 Implemented
CO0095 # 02 Y:1987 02 1987 INCREASE AMOUNT OF CONDENSATE RETURNED $19,460 $1,000 Implemented
CO0095 # 03 Y:1987 03 1987 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $3,467 $500 Not Implemented
CO0095 # 04 Y:1987 04 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $573 $500 Implemented
CO0095 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $2,502 $950 Not Implemented
CO0095 # 06 Y:1987 06 1987 REPAIR AND ELIMINATE STEAM LEAKS $4,535 $250 Implemented
CO0095 # 07 Y:1987 07 1987 INSTALL STEAM TRAP $483 $220 Implemented
CO0095 # 08 Y:1987 08 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $253 $300 Implemented
CO0095 # 09 Y:1987 09 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $581 $0 Not Implemented
UD0239 # 01 Y:1987 01 1987 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $2,627 $2,500 Implemented
UD0239 # 02 Y:1987 02 1987 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH $23,356 $10,000 Implemented
UD0239 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,341 $600 Implemented
UD0239 # 04 Y:1987 04 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,069 $6,000 Implemented
OR0003 # 01 Y:1987 01 1987 USE MINIMUM STEAM OPERATING PRESSURE $486 $0 Implemented
OR0003 # 02 Y:1987 02 1987 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $1,365 $45 Implemented
OR0003 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $2,130 $447 Implemented
OR0003 # 04 Y:1987 04 1987 MINIMIZE WATER USAGE $2,826 $10 Implemented
OR0003 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $432 $190 Implemented
OR0003 # 06 Y:1987 06 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $334 $246 Implemented
OR0003 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $740 $632 Not Implemented
OR0003 # 08 Y:1987 08 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $484 $300 Implemented
OR0003 # 09 Y:1987 09 1987 OPTIMIZE PLANT POWER FACTOR $1,632 $2,260 Not Implemented
OR0003 # 10 Y:1987 10 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,940 $7,000 Implemented
OR0003 # 11 Y:1987 11 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $470 $927 Implemented