Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,969
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0172 # 01 Y:1985 | 01 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $93,600 | $40,000 | Not Implemented |
KU0172 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,410 | $3,270 | Implemented |
KU0172 # 03 Y:1985 | 03 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $784 | $350 | Not Implemented |
KU0172 # 04 Y:1985 | 04 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $451 | $0 | Not Implemented |
KU0172 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $345 | $34 | Implemented |
CO0030 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,761 | $300 | Implemented |
CO0030 # 02 Y:1985 | 02 | 1985 | INSTALL TURBULATORS | $4,405 | $400 | Implemented |
CO0030 # 03 Y:1985 | 03 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,575 | $10,000 | Not Implemented |
CO0030 # 04 Y:1985 | 04 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,492 | $3,000 | Implemented |
CO0030 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,420 | $1,072 | Implemented |
CO0030 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $751 | $400 | Implemented |
CO0030 # 07 Y:1985 | 07 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $730 | $200 | Implemented |
CO0030 # 08 Y:1985 | 08 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,640 | $1,485 | Implemented |
CO0030 # 09 Y:1985 | 09 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,211 | $350 | Implemented |
CO0025 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,180 | $2,587 | Not Implemented |
CO0025 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,791 | $300 | Implemented |
CO0025 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,650 | $142 | Not Implemented |
CO0025 # 04 Y:1985 | 04 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,847 | $400 | Not Implemented |
CO0025 # 05 Y:1985 | 05 | 1985 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $253 | $100 | Not Implemented |
CO0025 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $117 | $100 | Not Implemented |
KU0119 # 01 Y:1984 | 01 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,545 | $16,000 | Implemented |
KU0119 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,576 | $5,000 | Not Implemented |
KU0119 # 03 Y:1984 | 03 | 1984 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,583 | $7,400 | Not Implemented |
KU0119 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,150 | $3,590 | Implemented |
KU0119 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,365 | $3,208 | Not Implemented |