Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
250
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0914 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,411 | $32,000 | Not Implemented |
OK0914 # 03 Y:2015 | 03 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,010 | $2,099 | Not Implemented |
OK0914 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,766 | $7,337 | Not Implemented |
OK0914 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,014 | $18,774 | Not Implemented |
OK0914 # 06 Y:2015 | 06 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,124 | $200 | Not Implemented |
OK0914 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,340 | $3,200 | Implemented |
OK0914 # 08 Y:2015 | 08 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $42,247 | $75,023 | Not Implemented |
OK0914 # 09 Y:2015 | 09 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $22,289 | $11,500 | Not Implemented |
OK0914 # 20 Y:2015 | 20 | 2015 | OPTIMIZE PLANT POWER FACTOR | $52,725 | $154,000 | Not Implemented |
OK0914 # 19 Y:2015 | 19 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,048 | $5,892 | Not Implemented |
OK0914 # 18 Y:2015 | 18 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,019 | $7,450 | Not Implemented |
OK0914 # 17 Y:2015 | 17 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,733 | $703 | Not Implemented |
OK0914 # 16 Y:2015 | 16 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $64,892 | $80,198 | Not Implemented |
OK0914 # 15 Y:2015 | 15 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,284 | $1,600 | Implemented |
OK0914 # 14 Y:2015 | 14 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,544 | $200 | Not Implemented |
OK0914 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,780 | $7,450 | Not Implemented |
OK0914 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,749 | $7,233 | Not Implemented |
OK0914 # 11 Y:2015 | 11 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,699 | $876 | Not Implemented |
OK0914 # 10 Y:2015 | 10 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,732 | $17,000 | Not Implemented |
AM0657 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,365 | $330 | Implemented |
AM0657 # 04 Y:2014 | 04 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,540 | $0 | Implemented |
AM0657 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $4,420 | $450 | Not Implemented |
AM0657 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,770 | $21,200 | Not Implemented |
AM0657 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,150 | $16,680 | Implemented |
AM0520 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,340 | $10,600 | Implemented |