Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,939
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0005 # 12 Y:2007 | 12 | 2007 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $34,728 | $1,615 | Not Implemented |
MI0147 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $20,581 | $16,000 | Implemented |
MI0147 # 02 Y:2007 | 02 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,498 | $1,750 | Implemented |
MI0147 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,305 | $7,878 | Implemented |
MI0147 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,950 | $1,074 | Not Implemented |
MI0147 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $481 | $30 | Not Implemented |
UD0763 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $36,135 | $5,242 | Implemented |
UD0763 # 02 Y:2007 | 02 | 2007 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $30,994 | $8,900 | Implemented |
UD0763 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,945 | $57,910 | Not Implemented |
UD0763 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,551 | $8,100 | Not Implemented |
UD0763 # 05 Y:2007 | 05 | 2007 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,275 | $0 | Not Implemented |
UD0763 # 06 Y:2007 | 06 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,835 | $3,670 | Not Implemented |
NC0362 # 01 Y:2007 | 01 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $43,646 | $70,525 | Not Implemented |
NC0362 # 02 Y:2007 | 02 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $75,775 | $79,525 | Not Implemented |
NC0362 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $3,512 | $3,546 | Not Implemented |
NC0362 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,160 | $50 | Not Implemented |
NC0362 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $295 | $537 | Not Implemented |
NC0362 # 06 Y:2007 | 06 | 2007 | MAKE A NEW BY-PRODUCT | $655,523 | $2,000,000 | Not Implemented |
IC0127 # 01 Y:2007 | 01 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $14,659 | $0 | Implemented |
IC0127 # 02 Y:2007 | 02 | 2007 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $800 | $440 | Implemented |
IC0127 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,063 | $51,889 | Implemented |
IC0127 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $1,026 | Implemented |
IC0127 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $36,459 | $0 | Implemented |
IC0127 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,336 | $20,976 | Implemented |
IC0127 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $3,818 | $886 | Implemented |