Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
108
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0217 # 04 Y:1987 | 04 | 1987 | INSTALL AUTOMATIC STACK DAMPER | $5,647 | $700 | Not Implemented |
KU0217 # 05 Y:1987 | 05 | 1987 | INSTALL TURBULATORS | $8,520 | $6,627 | Not Implemented |
KU0217 # 06 Y:1987 | 06 | 1987 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $549 | $500 | Implemented |
KU0217 # 07 Y:1987 | 07 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,186 | $4,170 | Implemented |
KU0217 # 08 Y:1987 | 08 | 1987 | IMPROVE LUBRICATION PRACTICES | $1,376 | $700 | Not Implemented |
KU0217 # 09 Y:1987 | 09 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,661 | $300 | Implemented |
KU0217 # 10 Y:1987 | 10 | 1987 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $19,971 | $15,800 | Not Implemented |
KU0172 # 01 Y:1985 | 01 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $93,600 | $40,000 | Not Implemented |
KU0172 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,410 | $3,270 | Implemented |
KU0172 # 03 Y:1985 | 03 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $784 | $350 | Not Implemented |
KU0172 # 04 Y:1985 | 04 | 1985 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $451 | $0 | Not Implemented |
KU0172 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $345 | $34 | Implemented |
KU0119 # 01 Y:1984 | 01 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,545 | $16,000 | Implemented |
KU0119 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,576 | $5,000 | Not Implemented |
KU0119 # 03 Y:1984 | 03 | 1984 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,583 | $7,400 | Not Implemented |
KU0119 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,150 | $3,590 | Implemented |
KU0119 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,365 | $3,208 | Not Implemented |
KU0119 # 06 Y:1984 | 06 | 1984 | INSTALL TURBULATORS | $2,558 | $1,261 | Not Implemented |
KU0119 # 07 Y:1984 | 07 | 1984 | OPERATE BOILERS ON HIGH FIRE SETTING | $2,034 | $50 | Implemented |
KU0119 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,240 | $0 | Implemented |
KU0119 # 09 Y:1984 | 09 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $982 | $200 | Implemented |
KU0119 # 10 Y:1984 | 10 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $939 | $0 | Not Implemented |
KU0119 # 11 Y:1984 | 11 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $486 | $465 | Not Implemented |
KU0119 # 12 Y:1984 | 12 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $393 | $50 | Implemented |
KU0119 # 13 Y:1984 | 13 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $288 | $120 | Not Implemented |