Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,939
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0257 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,389 | $90 | Not Implemented |
LL0257 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $182 | $420 | Not Implemented |
LL0256 # 01 Y:2006 | 01 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $219,845 | $2,900 | Implemented |
LL0256 # 02 Y:2006 | 02 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $111,471 | $70,939 | Implemented |
LL0256 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $35,700 | $11,209 | Implemented |
LL0256 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $20,392 | $3,960 | Implemented |
LL0256 # 05 Y:2006 | 05 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,350 | $720 | Not Implemented |
LL0256 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $7,057 | $1,330 | Implemented |
LL0256 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,368 | $30 | Not Implemented |
LL0256 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $2,768 | $210 | Not Implemented |
LL0256 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,347 | $640 | Implemented |
LL0256 # 10 Y:2006 | 10 | 2006 | USE PHOTOCELL CONTROLS | $870 | $90 | Implemented |
LL0256 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $785 | $700 | Implemented |
LL0255 # 01 Y:2006 | 01 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $76,757 | $77,280 | Not Implemented |
LL0255 # 02 Y:2006 | 02 | 2006 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $72,962 | $24,500 | Not Implemented |
LL0255 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $32,476 | $8,296 | Not Implemented |
LL0255 # 04 Y:2006 | 04 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $16,453 | $19,600 | Not Implemented |
LL0255 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,985 | $30 | Not Implemented |
LL0255 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,638 | $1,520 | Implemented |
LL0255 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $3,853 | $1,320 | Implemented |
LL0255 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $844 | $700 | Implemented |
LL0255 # 09 Y:2006 | 09 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $747 | $69 | Implemented |
LL0255 # 10 Y:2006 | 10 | 2006 | USE PHOTOCELL CONTROLS | $244 | $30 | Implemented |
AM0513 # 01 Y:2006 | 01 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $103,300 | $4,900 | Implemented |
AM0513 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $80,500 | $76,300 | Implemented |