Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,939
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0736 # 07 Y:2002 | 07 | 2002 | COVER OPEN TANKS | $3,121 | $6,000 | Not Implemented |
GT0736 # 08 Y:2002 | 08 | 2002 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $44,595 | $27,000 | Not Implemented |
GT0736 # 09 Y:2002 | 09 | 2002 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,580 | $0 | Implemented |
GT0736 # 10 Y:2002 | 10 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,745 | $31,000 | Not Implemented |
CO0495 # 01 Y:2001 | 01 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,590 | $17,000 | Implemented |
CO0495 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $1,860 | $500 | Implemented |
CO0495 # 03 Y:2001 | 03 | 2001 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $470 | $500 | Implemented |
CO0495 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $250 | $0 | Implemented |
CO0495 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $9,900 | $1,000 | Implemented |
GT0720 # 01 Y:2001 | 01 | 2001 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $337 | $1,000 | Implemented |
GT0720 # 02 Y:2001 | 02 | 2001 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,475 | $600 | Implemented |
GT0720 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $467 | $943 | Not Implemented |
GT0720 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,472 | $6,151 | Implemented |
GT0720 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $324 | Implemented |
GT0720 # 06 Y:2001 | 06 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $658 | $982 | Not Implemented |
GT0720 # 07 Y:2001 | 07 | 2001 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,320 | $50 | Implemented |
GT0720 # 08 Y:2001 | 08 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,740 | $0 | Not Implemented |
GT0720 # 09 Y:2001 | 09 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $93,750 | $1,700 | Not Implemented |
LE0117 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,452 | $2,500 | Implemented |
LE0117 # 02 Y:2001 | 02 | 2001 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,140 | $300 | Implemented |
LE0117 # 03 Y:2001 | 03 | 2001 | IMPROVE LUBRICATION PRACTICES | $221 | $100 | Implemented |
LE0117 # 04 Y:2001 | 04 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $644 | $1,300 | Implemented |
LE0117 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,335 | $1,700 | Not Implemented |
MA0491 # 01 Y:2001 | 01 | 2001 | USE EVAPORATION TO CONCENTRATE MATERIAL | $20,600 | $10,000 | Implemented |
MA0491 # 02 Y:2001 | 02 | 2001 | COVER OPEN TANKS | $2,300 | $0 | Not Implemented |