Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TP0009 # 08 Y:1999 | 08 | 1999 | ADD AREA LIGHTING SWITCHES | $82 | $0 | Implemented |
TP0009 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $627 | $0 | Implemented |
TP0009 # 06 Y:1999 | 06 | 1999 | INSTALL OCCUPANCY SENSORS | $123 | $182 | Implemented |
TP0009 # 05 Y:1999 | 05 | 1999 | USE SYNTHETIC LUBRICANT | $187 | $0 | Implemented |
TP0009 # 01 Y:1999 | 01 | 1999 | USE OPTIMUM THICKNESS INSULATION | $2,208 | $3,947 | Not Implemented |
TP0009 # 04 Y:1999 | 04 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $330 | $872 | Implemented |
TP0009 # 03 Y:1999 | 03 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $394 | $160 | Implemented |
TP0009 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $292 | Implemented |
KU0534 # 02 Y:1999 | 02 | 1999 | MINIMIZE WATER USAGE | $84,000 | $22,000 | Not Implemented |
KU0534 # 01 Y:1999 | 01 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,860 | $1,000 | Not Implemented |
KU0534 # 03 Y:1999 | 03 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $9,920 | $1,360 | Not Implemented |
NC0180 # 06 Y:1999 | 06 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $15,265 | $1,500 | Implemented |
NC0180 # 05 Y:1999 | 05 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $188 | $300 | Not Implemented |
NC0180 # 04 Y:1999 | 04 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,175 | $3,250 | Implemented |
NC0180 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,440 | $53,360 | Implemented |
NC0180 # 07 Y:1999 | 07 | 1999 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $47,820 | $68,000 | Implemented |
NC0180 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,282 | $1,500 | Implemented |
NC0180 # 01 Y:1999 | 01 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,324 | $2,000 | Implemented |
SF0178 # 01 Y:1999 | 01 | 1999 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,431 | $0 | Implemented |
SF0178 # 02 Y:1999 | 02 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $850 | $788 | Implemented |
SF0178 # 05 Y:1999 | 05 | 1999 | USE PHOTOCELL CONTROLS | $3,556 | $14,000 | Not Implemented |
SF0178 # 06 Y:1999 | 06 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $240 | $200 | Implemented |
SF0178 # 08 Y:1999 | 08 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,184 | $3,721 | Not Implemented |
SF0178 # 09 Y:1999 | 09 | 1999 | TREAT AND REUSE RINSE WATERS | $3,340 | $3,269 | Implemented |
SF0178 # 07 Y:1999 | 07 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $10,000 | $200 | Implemented |