Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 201 | Meat Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0495 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $250 | $0 | Implemented |
CO0495 # 03 Y:2001 | 03 | 2001 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $470 | $500 | Implemented |
CO0495 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $1,860 | $500 | Implemented |
CO0495 # 01 Y:2001 | 01 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,590 | $17,000 | Implemented |
CO0495 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $9,900 | $1,000 | Implemented |
GT0720 # 01 Y:2001 | 01 | 2001 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $337 | $1,000 | Implemented |
GT0720 # 09 Y:2001 | 09 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $93,750 | $1,700 | Not Implemented |
GT0720 # 08 Y:2001 | 08 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,740 | $0 | Not Implemented |
GT0720 # 07 Y:2001 | 07 | 2001 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,320 | $50 | Implemented |
GT0720 # 06 Y:2001 | 06 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $658 | $982 | Not Implemented |
GT0720 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $324 | Implemented |
GT0720 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,472 | $6,151 | Implemented |
GT0720 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $467 | $943 | Not Implemented |
GT0720 # 02 Y:2001 | 02 | 2001 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,475 | $600 | Implemented |
LE0117 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,452 | $2,500 | Implemented |
LE0117 # 04 Y:2001 | 04 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $644 | $1,300 | Implemented |
LE0117 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,335 | $1,700 | Not Implemented |
LE0117 # 02 Y:2001 | 02 | 2001 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,140 | $300 | Implemented |
LE0117 # 03 Y:2001 | 03 | 2001 | IMPROVE LUBRICATION PRACTICES | $221 | $100 | Implemented |
MA0491 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $600 | Not Implemented |
MA0491 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $410 | $85 | Implemented |
MA0491 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $500 | $150 | Implemented |
MA0491 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $800 | $100 | Implemented |
MA0491 # 02 Y:2001 | 02 | 2001 | COVER OPEN TANKS | $2,300 | $0 | Not Implemented |
MA0491 # 01 Y:2001 | 01 | 2001 | USE EVAPORATION TO CONCENTRATE MATERIAL | $20,600 | $10,000 | Implemented |