IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

774

matching recommendations
Reset
SIC 2011 Meat Packing Plants
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0036 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $477 $1,603 Not Implemented
UF0036 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21 $4,164 Not Implemented
UF0036 # 05 Y:1992 05 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $29 $75 Not Implemented
UF0036 # 06 Y:1992 06 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $24,728 $42,000 Not Implemented
CO0240 # 01 Y:1992 01 1992 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $970 $300 Implemented
CO0240 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $330 $125 Implemented
CO0240 # 03 Y:1992 03 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $785 $250 Implemented
CO0240 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $470 $290 Implemented
CO0240 # 05 Y:1992 05 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $290 $800 Implemented
CO0240 # 06 Y:1992 06 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $790 $3,090 Implemented
CO0240 # 07 Y:1992 07 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $180 $30 Implemented
KU0358 # 01 Y:1991 01 1991 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $35,057 $12,000 Not Implemented
KU0358 # 02 Y:1991 02 1991 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $14,710 $12,800 Not Implemented
KU0358 # 03 Y:1991 03 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $15,900 $38,600 Not Implemented
KU0358 # 04 Y:1991 04 1991 RECOVER WASTE HEAT FROM EQUIPMENT $18,286 $39,000 Not Implemented
KU0358 # 05 Y:1991 05 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $622 $0 Not Implemented
KU0358 # 06 Y:1991 06 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $156 $280 Not Implemented
OR0130 # 01 Y:1991 01 1991 INSTALL SET-BACK TIMERS $1,778 $225 Implemented
OR0130 # 02 Y:1991 02 1991 ELIMINATE LEAKS IN WATER LINES AND VALVES $261 $0 Implemented
OR0130 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $450 $800 Implemented
OR0130 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,399 $4,936 Implemented
OR0130 # 05 Y:1991 05 1991 OPTIMIZE PLANT POWER FACTOR $1,647 $3,450 Implemented
OR0130 # 06 Y:1991 06 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $75 $157 Implemented
OR0130 # 07 Y:1991 07 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,347 $3,453 Implemented
OR0130 # 08 Y:1991 08 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $292 $881 Implemented