IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22

matching recommendations
Reset
SIC 2011 Meat Packing Plants
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0302 # 05 Y:2004 05 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $5,988 $0 Implemented
NC0302 # 04 Y:2004 04 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $372 $0 Implemented
NC0302 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $953 $100 Implemented
NC0302 # 02 Y:2004 02 2004 AVOID FROST FORMATION ON EVAPORATORS $5,926 $19,000 Not Implemented
NC0302 # 01 Y:2004 01 2004 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $59,627 $136,000 Implemented
NC0172 # 02 Y:1999 02 1999 OPERATE BOILERS ON HIGH FIRE SETTING $4,485 $0 Not Implemented
NC0172 # 09 Y:1999 09 1999 MINIMIZE WATER USAGE $1,235 $1,200 Not Implemented
NC0172 # 08 Y:1999 08 1999 MINIMIZE WATER USAGE $2,627 $2,500 Not Implemented
NC0172 # 07 Y:1999 07 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $188 $300 Not Implemented
NC0172 # 06 Y:1999 06 1999 AVOID REWINDING MOTORS MORE THAN TWICE $10,026 $25,900 Not Implemented
NC0172 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $71,741 $40,000 Not Implemented
NC0172 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,986 $40 Not Implemented
NC0172 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $636 $476 Not Implemented
NC0172 # 01 Y:1999 01 1999 $125,000 $52,000 Not Implemented
OD0046 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $578 $1,512 Implemented
OD0046 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,356 $1,603 Not Implemented
OD0046 # 03 Y:1996 03 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $6,166 $3,150 Not Implemented
OD0046 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,088 $240 Implemented
OD0046 # 05 Y:1996 05 1996 USE SYNTHETIC LUBRICANT $757 $312 Not Implemented
OD0046 # 06 Y:1996 06 1996 INSTALL OCCUPANCY SENSORS $181 $354 Not Implemented
OD0046 # 07 Y:1996 07 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $39,000 $0 Implemented
OD0046 # 08 Y:1996 08 1996 RECOVER AND REUSE COOLING WATER $3,072 $8,100 Not Implemented