Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0508 # 05 Y:2021 | 05 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,407 | $24,000 | Implemented |
LE0508 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,625 | $3,000 | Implemented |
LE0508 # 03 Y:2021 | 03 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,110 | $10,000 | Implemented |
LE0508 # 02 Y:2021 | 02 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,709 | $29,000 | Not Implemented |
LE0508 # 01 Y:2021 | 01 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,328 | $100 | Implemented |
LE0382 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $11,599 | $0 | Implemented |
LE0382 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,433 | $8,016 | Implemented |
LE0382 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $792 | $2,500 | Not Implemented |
LE0382 # 05 Y:2014 | 05 | 2014 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $2,534 | $4,030 | Not Implemented |
LE0382 # 04 Y:2014 | 04 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $1,431 | $1,516 | Not Implemented |
LE0382 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,119 | $0 | Implemented |
LE0382 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $555 | $0 | Implemented |
LE0238 # 01 Y:2006 | 01 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,077,481 | $2,403,050 | Not Implemented |
LE0238 # 11 Y:2006 | 11 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,065 | $90 | Implemented |
LE0238 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,471 | $2,500 | Not Implemented |
LE0238 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,223 | $1,000 | Not Implemented |
LE0238 # 08 Y:2006 | 08 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,409 | $3,000 | Not Implemented |
LE0238 # 07 Y:2006 | 07 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,609 | $45,000 | Implemented |
LE0238 # 06 Y:2006 | 06 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,870 | $3,000 | Implemented |
LE0238 # 05 Y:2006 | 05 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,103 | $2,500 | Implemented |
LE0238 # 04 Y:2006 | 04 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $124,858 | $17,600 | Not Implemented |
LE0238 # 03 Y:2006 | 03 | 2006 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $335,810 | $500 | Implemented |
LE0238 # 02 Y:2006 | 02 | 2006 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $902,617 | $540,000 | Not Implemented |