Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0495 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $1,860 | $500 | Implemented |
CO0495 # 03 Y:2001 | 03 | 2001 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $470 | $500 | Implemented |
CO0495 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $250 | $0 | Implemented |
CO0495 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $9,900 | $1,000 | Implemented |
CO0495 # 01 Y:2001 | 01 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,590 | $17,000 | Implemented |
LE0117 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,335 | $1,700 | Not Implemented |
LE0117 # 04 Y:2001 | 04 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $644 | $1,300 | Implemented |
LE0117 # 03 Y:2001 | 03 | 2001 | IMPROVE LUBRICATION PRACTICES | $221 | $100 | Implemented |
LE0117 # 02 Y:2001 | 02 | 2001 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,140 | $300 | Implemented |
LE0117 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,452 | $2,500 | Implemented |
GT0707 # 06 Y:2001 | 06 | 2001 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $7,808 | $0 | Implemented |
GT0707 # 07 Y:2001 | 07 | 2001 | MODIFY STARTUP/SHUTDOWN TIMES | $45,820 | $0 | Implemented |
GT0707 # 08 Y:2001 | 08 | 2001 | INSTALL OCCUPANCY SENSORS | $179 | $250 | Not Implemented |
GT0707 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $103 | $72 | Implemented |
GT0707 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,680 | $3,496 | Not Implemented |
GT0707 # 03 Y:2001 | 03 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $2,040 | $6,700 | Implemented |
GT0707 # 02 Y:2001 | 02 | 2001 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $6,057 | $5,500 | Not Implemented |
GT0707 # 01 Y:2001 | 01 | 2001 | KEEP BOILER TUBES CLEAN | $5,290 | $3,000 | Not Implemented |