Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
14
matching recommendationsSIC | 2015 | Poultry Slaughtering And Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0162 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $853 | $0 | Not Implemented |
UF0162 # 02 Y:1996 | 02 | 1996 | DISCONNECT BALLASTS | $1,934 | $655 | Implemented |
UF0162 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $982 | $576 | Not Implemented |
UF0162 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,309 | $9,372 | Implemented |
UF0162 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,167 | $4,200 | Not Implemented |
UF0162 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,640 | $3,500 | Not Implemented |
UF0162 # 07 Y:1996 | 07 | 1996 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $1,074 | $0 | Not Implemented |
UF0106 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,268 | $2,638 | Implemented |
UF0106 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,054 | $17,625 | Implemented |
UF0106 # 03 Y:1995 | 03 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,861 | $1,000 | Implemented |
UF0106 # 04 Y:1995 | 04 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,255 | $5,200 | Not Implemented |
UF0106 # 05 Y:1995 | 05 | 1995 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $189,560 | $950,000 | Not Implemented |
UF0106 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $925 | $1,425 | Implemented |
UF0106 # 07 Y:1995 | 07 | 1995 | OPERATE BOILERS ON HIGH FIRE SETTING | $5,249 | $0 | Not Implemented |