Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,791
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0265 # 04 Y:1985 | 04 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,386 | $75 | Implemented |
TN0265 # 05 Y:1985 | 05 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,474 | $7,430 | Implemented |
TN0265 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $896 | $115 | Implemented |
TN0265 # 07 Y:1985 | 07 | 1985 | INSTALL SET-BACK TIMERS | $498 | $0 | Implemented |
LT0033 # 01 Y:1985 | 01 | 1985 | OPTIMIZE PLANT POWER FACTOR | $10,900 | $12,000 | Implemented |
LT0033 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,092 | $400 | Implemented |
LT0033 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,004 | $1,862 | Implemented |
LT0033 # 04 Y:1985 | 04 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,254 | $510 | Implemented |
LT0033 # 05 Y:1985 | 05 | 1985 | INSULATE BARE EQUIPMENT | $142 | $225 | Implemented |
LT0033 # 06 Y:1985 | 06 | 1985 | INSULATE BARE EQUIPMENT | $302 | $226 | Implemented |
LT0033 # 07 Y:1985 | 07 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,592 | $2,250 | Implemented |
LT0033 # 08 Y:1985 | 08 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $872 | $300 | Implemented |
LT0033 # 09 Y:1985 | 09 | 1985 | INSULATE BARE EQUIPMENT | $673 | $438 | Implemented |
CO0037 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $229 | $50 | Not Implemented |
CO0037 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,071 | $500 | Implemented |
CO0037 # 03 Y:1985 | 03 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,658 | $8,000 | Not Implemented |
CO0037 # 04 Y:1985 | 04 | 1985 | INSTALL TURBULATORS | $2,037 | $1,200 | Not Implemented |
CO0037 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $293 | $150 | Not Implemented |
CO0037 # 06 Y:1985 | 06 | 1985 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,718 | $960 | Implemented |
CO0037 # 07 Y:1985 | 07 | 1985 | INSULATE BARE EQUIPMENT | $2,299 | $1,000 | Implemented |
CO0037 # 08 Y:1985 | 08 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,507 | $812 | Not Implemented |
KU0165 # 01 Y:1985 | 01 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $28,837 | $33,000 | Implemented |
KU0165 # 02 Y:1985 | 02 | 1985 | HEAT WATER WITH EXHAUST HEAT | $20,949 | $37,000 | Implemented |
KU0165 # 03 Y:1985 | 03 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,822 | $9,000 | Not Implemented |
KU0165 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,248 | $4,815 | Implemented |