Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,773

matching recommendations
Reset
SIC 202 Dairy Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0037 # 06 Y:1985 06 1985 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,718 $960 Implemented
CO0037 # 07 Y:1985 07 1985 INSULATE BARE EQUIPMENT $2,299 $1,000 Implemented
CO0037 # 08 Y:1985 08 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,507 $812 Not Implemented
KU0165 # 01 Y:1985 01 1985 INCREASE AMOUNT OF CONDENSATE RETURNED $28,837 $33,000 Implemented
KU0165 # 02 Y:1985 02 1985 HEAT WATER WITH EXHAUST HEAT $20,949 $37,000 Implemented
KU0165 # 03 Y:1985 03 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $16,822 $9,000 Not Implemented
KU0165 # 04 Y:1985 04 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,248 $4,815 Implemented
KU0165 # 05 Y:1985 05 1985 IMPROVE LUBRICATION PRACTICES $10,224 $8,000 Implemented
KU0165 # 06 Y:1985 06 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,321 $1,020 Implemented
KU0165 # 07 Y:1985 07 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,984 $50 Implemented
KU0165 # 08 Y:1985 08 1985 RECOVER WASTE HEAT FROM EQUIPMENT $998 $450 Implemented
KU0165 # 09 Y:1985 09 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $468 $400 Implemented
KU0165 # 10 Y:1985 10 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $484 $400 Implemented
OK0166 # 01 Y:1985 01 1985 ELIMINATE LEAKS IN WATER LINES AND VALVES $3,054 $850 Not Implemented
OK0166 # 02 Y:1985 02 1985 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $34,175 $6,260 Not Implemented
OK0166 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $5,377 $2,398 Implemented
OK0166 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,074 $403 Not Implemented
OK0166 # 05 Y:1985 05 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,782 $30,000 Not Implemented
OK0166 # 06 Y:1985 06 1985 INSULATE BARE EQUIPMENT $950 $624 Implemented
MA0022 # 01 Y:1985 01 1985 HEAT WATER WITH EXHAUST HEAT $2,163 $1,875 Not Implemented
MA0022 # 02 Y:1985 02 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $753 $1,827 Implemented
MA0022 # 03 Y:1985 03 1985 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $160 $154 Implemented
MA0022 # 04 Y:1985 04 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $283 $0 Implemented
MA0022 # 05 Y:1985 05 1985 OPTIMIZE PLANT POWER FACTOR $432 $289 Implemented
MA0022 # 06 Y:1985 06 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,060 $1,190 Not Implemented