Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0161 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $290 | $300 | Implemented |
CO0161 # 03 Y:1989 | 03 | 1989 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $300 | $100 | Implemented |
CO0161 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $105 | Implemented |
CO0161 # 05 Y:1989 | 05 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $390 | $330 | Implemented |
CO0161 # 06 Y:1989 | 06 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $280 | $0 | Implemented |
CO0161 # 07 Y:1989 | 07 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $214 | $350 | Not Implemented |
CO0161 # 08 Y:1989 | 08 | 1989 | TURN OFF STEAM TRACING DURING MILD WEATHER | $170 | $200 | Implemented |
CO0161 # 01 Y:1989 | 01 | 1989 | AVOID FROST FORMATION ON EVAPORATORS | $1,340 | $3,000 | Not Implemented |
MA0153 # 05 Y:1989 | 05 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,985 | $1,910 | Not Implemented |
MA0153 # 07 Y:1989 | 07 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,615 | $3,000 | Not Implemented |
MA0153 # 06 Y:1989 | 06 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $530 | $218 | Not Implemented |
MA0153 # 04 Y:1989 | 04 | 1989 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $19,722 | $115,000 | Not Implemented |
MA0153 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,825 | $500 | Implemented |
MA0153 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $878 | $163 | Implemented |
MA0153 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $632 | $217 | Not Implemented |
WI0050 # 01 Y:1989 | 01 | 1989 | IMPROVE LUBRICATION PRACTICES | $4,124 | $0 | Not Implemented |
WI0050 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $821 | $0 | Not Implemented |
WI0050 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84 | $713 | Not Implemented |
WI0050 # 04 Y:1989 | 04 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,651 | $0 | Not Implemented |
WI0050 # 05 Y:1989 | 05 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,920 | $0 | Not Implemented |
WI0050 # 06 Y:1989 | 06 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,290 | $6,000 | Not Implemented |
WI0050 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $325 | $500 | Not Implemented |
WI0050 # 08 Y:1989 | 08 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $957 | $5,000 | Not Implemented |
WI0050 # 09 Y:1989 | 09 | 1989 | HEAT WATER WITH EXHAUST HEAT | $5,408 | $10,000 | Not Implemented |