Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 2023 | Dry, Condensed, Evaporated Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0592 # 02 Y:2020 | 02 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,440 | $12,400 | Implemented |
SD0592 # 03 Y:2020 | 03 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,470 | $13,092 | Implemented |
SD0592 # 05 Y:2020 | 05 | 2020 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,751 | $5,661 | Implemented |
SD0592 # 01 Y:2020 | 01 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $61,433 | $149,300 | Implemented |
SF0492 # 11 Y:2016 | 11 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,365 | $30,659 | Implemented |
SF0492 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $8,681 | $17,643 | Implemented |
SF0492 # 09 Y:2016 | 09 | 2016 | INSULATE BARE EQUIPMENT | $165 | $292 | Implemented |
SF0492 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $7,565 | $13,378 | Implemented |
SF0492 # 07 Y:2016 | 07 | 2016 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,867 | $11,727 | Implemented |
SF0492 # 06 Y:2016 | 06 | 2016 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $8,794 | $15,281 | Implemented |
SF0492 # 05 Y:2016 | 05 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,830 | $14,614 | Implemented |
SF0492 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,543 | $7,437 | Implemented |
SF0492 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,076 | $5,200 | Implemented |
SF0492 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $218 | $33 | Implemented |
SF0492 # 01 Y:2016 | 01 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,265 | $280 | Implemented |
SF0219 # 06 Y:2001 | 06 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $14,216 | $507 | Implemented |
SF0219 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $529 | $840 | Implemented |
SF0219 # 03 Y:2001 | 03 | 2001 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $415 | $406 | Implemented |
SF0219 # 02 Y:2001 | 02 | 2001 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $5,816 | $5,705 | Implemented |
SF0219 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,206 | $0 | Implemented |
SF0067 # 08 Y:1995 | 08 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,803 | $0 | Implemented |
SF0067 # 07 Y:1995 | 07 | 1995 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $696 | $850 | Implemented |
SF0067 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $758 | $450 | Implemented |
SF0067 # 04 Y:1995 | 04 | 1995 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,075 | $0 | Implemented |
SF0067 # 03 Y:1995 | 03 | 1995 | INSTALL OCCUPANCY SENSORS | $3,408 | $1,478 | Implemented |