Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsSIC | 2026 | Fluid Milk |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0586 # 02 Y:2000 | 02 | 2000 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $99,635 | $350,000 | Not Implemented |
UD0586 # 03 Y:2000 | 03 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $96,665 | $5,000 | Not Implemented |
UD0586 # 04 Y:2000 | 04 | 2000 | MINIMIZE WATER USAGE | $18,654 | $298 | Implemented |
UD0586 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,183 | $0 | Implemented |
UD0586 # 06 Y:2000 | 06 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,583 | $0 | Not Implemented |
WV0109 # 10 Y:1997 | 10 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $46,800 | $0 | Not Implemented |
WV0109 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,527 | $5,295 | Implemented |
WV0109 # 02 Y:1997 | 02 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,337 | $384 | Implemented |
WV0109 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $616 | $478 | Not Implemented |
WV0109 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $962 | $15 | Not Implemented |
WV0109 # 05 Y:1997 | 05 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $26,265 | $3,000 | Implemented |
WV0109 # 06 Y:1997 | 06 | 1997 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $7,904 | $6,300 | Implemented |
WV0109 # 07 Y:1997 | 07 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,550 | $441 | Implemented |
WV0109 # 08 Y:1997 | 08 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $35,000 | $5,000 | Not Implemented |
WV0109 # 09 Y:1997 | 09 | 1997 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $5,200 | $200 | Not Implemented |
UD0434 # 05 Y:1994 | 05 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,045 | $300 | Implemented |
UD0434 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,504 | $12,960 | Implemented |
UD0434 # 03 Y:1994 | 03 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $13,081 | $0 | Implemented |
UD0434 # 02 Y:1994 | 02 | 1994 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $14,462 | $7,500 | Implemented |
UD0434 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $4,831 | $8,000 | Implemented |
UD0034 # 05 Y:1982 | 05 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $761 | $400 | Not Implemented |
UD0034 # 04 Y:1982 | 04 | 1982 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $46,072 | $120,000 | Not Implemented |
UD0034 # 03 Y:1982 | 03 | 1982 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $252 | $100 | Not Implemented |
UD0034 # 02 Y:1982 | 02 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $851 | $0 | Implemented |
UD0034 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,098 | $2,149 | Not Implemented |