Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

134

matching recommendations
Reset
SIC 2026 Fluid Milk
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0685 # 05 Y:2014 05 2014 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,210 $1,500 Implemented
CO0685 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $1,890 $8,590 Implemented
CO0685 # 03 Y:2014 03 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $1,750 $610 Implemented
CO0685 # 02 Y:2014 02 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,740 $4,240 Implemented
CO0685 # 01 Y:2014 01 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,910 $13,360 Implemented
CO0585 # 10 Y:2006 10 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $290 $200 Implemented
CO0585 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $719 $110 Implemented
CO0585 # 08 Y:2006 08 2006 USE SOLAR HEAT TO MAKE ELECTRICTY $1,430 $2,950 Not Implemented
CO0585 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,720 $3,590 Implemented
CO0585 # 06 Y:2006 06 2006 USE SOLAR HEAT TO HEAT MAKE-UP AIR $3,460 $29,620 Not Implemented
CO0585 # 05 Y:2006 05 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $142 $194 Implemented
CO0585 # 04 Y:2006 04 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $1,120 $0 Implemented
CO0585 # 03 Y:2006 03 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,160 $3,230 Not Implemented
CO0585 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,420 $180 Implemented
CO0585 # 01 Y:2006 01 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,850 $15,000 Not Implemented
CO0192 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $100 $283 Implemented
CO0192 # 01 Y:1990 01 1990 HEAT WATER WITH EXHAUST HEAT $9,236 $16,000 Not Implemented
CO0192 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,367 $1,042 Implemented
CO0192 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,400 $6,000 Implemented
CO0192 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,600 $2,000 Implemented
CO0192 # 06 Y:1990 06 1990 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,800 $6,000 Not Implemented
CO0192 # 05 Y:1990 05 1990 MAINTAIN STEAM JETS USED FOR VACUUM SYSTEM $4,700 $1,600 Implemented
CO0192 # 07 Y:1990 07 1990 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,400 $5,000 Not Implemented
CO0186 # 07 Y:1990 07 1990 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $665 $100 Implemented
CO0186 # 05 Y:1990 05 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,240 $600 Not Implemented