IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,945

matching recommendations
Reset
SIC 203 Preserved Fruits And Vegetables
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0264 # 01 Y:2025 01 2025 INSTALL AUTOMATIC BOILER FUEL FEED SYSTEM $79,422 $143,652 Not Implemented
UU0264 # 09 Y:2025 09 2025 USE SOLAR HEAT TO MAKE ELECTRICTY $44,517 $717,537 Not Implemented
UU0264 # 06 Y:2025 06 2025 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,905 $7,317 Implemented
UU0264 # 03 Y:2025 03 2025 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $729,671 $3,645,455 Implemented
UU0264 # 08 Y:2025 08 2025 INSTALL OCCUPANCY SENSORS $538 $1,531 Not Implemented
UU0264 # 04 Y:2025 04 2025 REPLACE BOILER $379,077 $4,080,441 Implemented
UU0264 # 11 Y:2025 11 2025 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $44,506 $432,000 Implemented
UU0264 # 10 Y:2025 10 2025 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $515 $916 Implemented
UU0264 # 05 Y:2025 05 2025 UPGRADE CONTROLS ON COMPRESSORS $3,332 $4,000 Implemented
UU0264 # 02 Y:2025 02 2025 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $215,672 $730,950 Implemented
UU0264 # 07 Y:2025 07 2025 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,405 $8,915 Implemented
DL0247 # 03 Y:2025 03 2025 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,671 $0 n/a
DL0247 # 04 Y:2025 04 2025 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS $1,592 $0 n/a
DL0247 # 06 Y:2025 06 2025 TURN OFF EQUIPMENT WHEN NOT IN USE $993 $0 n/a
DL0247 # 01 Y:2025 01 2025 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $350 $0 n/a
DL0247 # 02 Y:2025 02 2025 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,382 $0 n/a
DL0247 # 07 Y:2025 07 2025 METER WASTE WATER $34,580 $145 n/a
DL0247 # 08 Y:2025 08 2025 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $27,958 $200,000 n/a
DL0247 # 09 Y:2025 09 2025 UTILIZE A LESS EXPENSIVE COOLING METHOD $116,551 $1,000,000 n/a
DL0247 # 05 Y:2025 05 2025 TURN OFF EQUIPMENT WHEN NOT IN USE $399 $0 n/a
OR0802 # 01 Y:2024 01 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,248 $147 Not Implemented
OR0802 # 04 Y:2024 04 2024 REPLACE BOILER $37,073 $222,038 Implemented
OR0802 # 02 Y:2024 02 2024 INSULATE BARE EQUIPMENT $2,952 $500 Not Implemented
OR0802 # 03 Y:2024 03 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,483 $499 Not Implemented
AS0590 # 04 Y:2024 04 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,358 $1,128 n/a