Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,930
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0011 # 07 Y:1987 | 07 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,024 | $1,092 | Implemented |
OR0011 # 08 Y:1987 | 08 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $777 | $746 | Implemented |
OR0004 # 01 Y:1987 | 01 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $617 | $0 | Not Implemented |
OR0004 # 02 Y:1987 | 02 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $720 | $0 | Implemented |
OR0004 # 03 Y:1987 | 03 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $674 | $0 | Not Implemented |
OR0004 # 04 Y:1987 | 04 | 1987 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $98,800 | $0 | Implemented |
OR0004 # 05 Y:1987 | 05 | 1987 | HEAT WATER WITH EXHAUST HEAT | $28,800 | $9,000 | Not Implemented |
OR0004 # 06 Y:1987 | 06 | 1987 | INSULATE BARE EQUIPMENT | $1,008 | $528 | Implemented |
OR0004 # 07 Y:1987 | 07 | 1987 | INSTALL SET-BACK TIMERS | $546 | $395 | Implemented |
OR0004 # 08 Y:1987 | 08 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,301 | $4,205 | Not Implemented |
OR0004 # 09 Y:1987 | 09 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $275 | $356 | Implemented |
OR0004 # 10 Y:1987 | 10 | 1987 | OPTIMIZE PLANT POWER FACTOR | $3,680 | $5,110 | Implemented |
OR0004 # 11 Y:1987 | 11 | 1987 | REDESIGN PROCESS | $1,577 | $2,610 | Not Implemented |
GT0306 # 01 Y:1987 | 01 | 1987 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $23,465 | $0 | Implemented |
GT0306 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $565 | $300 | Implemented |
GT0306 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,954 | $20,000 | Not Implemented |
GT0306 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $187 | $102 | Not Implemented |
GT0306 # 05 Y:1987 | 05 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $563 | $778 | Not Implemented |
MA0048 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $592 | $180 | Implemented |
MA0048 # 02 Y:1985 | 02 | 1985 | INSTALL TURBULATORS | $636 | $2,200 | Implemented |
MA0048 # 03 Y:1985 | 03 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $728 | $1,700 | Not Implemented |
MA0048 # 04 Y:1985 | 04 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,960 | $2,710 | Not Implemented |
MA0048 # 05 Y:1985 | 05 | 1985 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,082 | $2,095 | Not Implemented |
MA0048 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,733 | $9,000 | Not Implemented |
TN0237 # 01 Y:1984 | 01 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,114 | $2,500 | Not Implemented |