Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
SIC 203 Preserved Fruits And Vegetables
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0605 # 09 Y:1996 09 1996 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $260,000 $49,800 Implemented
UF0165 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,572 $32,094 Not Implemented
UF0165 # 05 Y:1996 05 1996 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $10,500 $400 Not Implemented
UF0165 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,091 $2,802 Not Implemented
UF0165 # 04 Y:1996 04 1996 CLEAN CONDENSER TUBES $19,869 $0 Implemented
UF0165 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,841 $1,350 Implemented
GT0578 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,090 $34,520 Implemented
GT0578 # 05 Y:1996 05 1996 USE DEMAND CONTROLLER OR LOAD SHEDDER $21,460 $0 Not Implemented
GT0578 # 04 Y:1996 04 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $3,970 $500 Implemented
GT0578 # 03 Y:1996 03 1996 INCREASE AMOUNT OF CONDENSATE RETURNED $27,914 $12,000 Implemented
GT0578 # 02 Y:1996 02 1996 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,045 $1,000 Implemented
GT0578 # 01 Y:1996 01 1996 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $21,137 $50,000 Implemented
GT0578 # 07 Y:1996 07 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $850 $2,100 Not Implemented
UF0058 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,572 $1,475 Implemented
UF0058 # 02 Y:1993 02 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $5,100 $8,400 Not Implemented
UF0058 # 06 Y:1993 06 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,220 $30,000 Not Implemented
UF0058 # 05 Y:1993 05 1993 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $17,336 $63,000 Not Implemented
UF0058 # 04 Y:1993 04 1993 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $390 $590 Not Implemented
UF0058 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $652 $1,482 Not Implemented
GT0306 # 01 Y:1987 01 1987 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $23,465 $0 Implemented
GT0306 # 02 Y:1987 02 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $565 $300 Implemented
GT0306 # 03 Y:1987 03 1987 RECOVER WASTE HEAT FROM EQUIPMENT $11,954 $20,000 Not Implemented
GT0306 # 04 Y:1987 04 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $187 $102 Not Implemented
GT0306 # 05 Y:1987 05 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $563 $778 Not Implemented
GT0154 # 03 Y:1982 03 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,641 $102,476 Not Implemented