Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0347 # 05 Y:2013 | 05 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $185 | $570 | Not Implemented |
SU0347 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $491 | $935 | Not Implemented |
SU0347 # 03 Y:2013 | 03 | 2013 | ELIMINATE/REDUCE AN OPERATION | $10,027 | $5,789 | Not Implemented |
LE0339 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $2,652 | $3,590 | Not Implemented |
LE0339 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,689 | $3,000 | Not Implemented |
LE0339 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,390 | $13,920 | Not Implemented |
LE0339 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,612 | $13,428 | Implemented |
LE0339 # 05 Y:2012 | 05 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,198 | $9,800 | Implemented |
LE0339 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,354 | $70,000 | Not Implemented |
LE0339 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,280 | $1,000 | Implemented |
LE0339 # 08 Y:2012 | 08 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,007 | $20,000 | Not Implemented |
LE0339 # 09 Y:2012 | 09 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $28,832 | $20,000 | Not Implemented |
LE0339 # 10 Y:2012 | 10 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $13,433 | $0 | Implemented |
LE0339 # 11 Y:2012 | 11 | 2012 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $59,246 | $10,500 | Not Implemented |
SU0303 # 01 Y:2011 | 01 | 2011 | INSULATE FEEDWATER TANK | $273 | $83 | Implemented |
SU0303 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,814 | $10,990 | Not Implemented |
SU0303 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $858 | $486 | Implemented |
SU0303 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,973 | $9,016 | Not Implemented |
SU0303 # 05 Y:2011 | 05 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $103 | $275 | Not Implemented |
SU0303 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $104 | $128 | Implemented |
SU0303 # 07 Y:2011 | 07 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $4,074 | $16,668 | Not Implemented |
SU0295 # 03 Y:2010 | 03 | 2010 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $595,177 | $272,656 | Implemented |
SU0295 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,178 | $1,225 | Implemented |
SU0295 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,403 | $27,649 | Implemented |
SU0295 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,943 | $74,298 | Implemented |