Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0295 # 03 Y:2010 | 03 | 2010 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $595,177 | $272,656 | Implemented |
SU0295 # 02 Y:2010 | 02 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,022 | $0 | Not Implemented |
SU0295 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,943 | $74,298 | Implemented |
SU0295 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,574 | $0 | Implemented |
SU0208 # 02 Y:2005 | 02 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $71,711 | $7,200 | Not Implemented |
SU0208 # 01 Y:2005 | 01 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,549 | $0 | Implemented |
SU0208 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,385 | $1,250 | Implemented |
SU0208 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,644 | $1,626 | Implemented |
SU0208 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,067 | $1,456 | Implemented |
SU0208 # 06 Y:2005 | 06 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $137,714 | $144,177 | Implemented |
SU0208 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,975 | $26,200 | Not Implemented |
SU0206 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,971 | $0 | Not Implemented |
SU0206 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,139 | $1,148 | Implemented |
SU0206 # 03 Y:2005 | 03 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,234 | $1,352 | Implemented |
SU0206 # 04 Y:2005 | 04 | 2005 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $255,262 | $207,240 | Implemented |
SU0206 # 05 Y:2005 | 05 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $102,975 | $200,000 | n/a |
SU0198 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,691 | $736 | Implemented |
SU0198 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $925 | $401 | Not Implemented |
SU0198 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,416 | $883 | Implemented |
SU0198 # 06 Y:2004 | 06 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $25,497 | $15,000 | Implemented |
SU0198 # 02 Y:2004 | 02 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,671 | $133 | Implemented |
SU0198 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,681 | $0 | Implemented |
SU0175 # 08 Y:2004 | 08 | 2004 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $9,162 | $8,765 | Not Implemented |
SU0175 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $510 | $468 | Implemented |
SU0175 # 06 Y:2004 | 06 | 2004 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $9,764 | $8,647 | Implemented |