Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,930
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0249 # 01 Y:2003 | 01 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $106,883 | $3,200 | Implemented |
BD0249 # 02 Y:2003 | 02 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $73,616 | $4,000 | Implemented |
BD0249 # 03 Y:2003 | 03 | 2003 | INSTALL TURBULATORS | $20,715 | $4,800 | Not Implemented |
BD0249 # 04 Y:2003 | 04 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $13,506 | $250 | Implemented |
BD0249 # 05 Y:2003 | 05 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,077 | $20,000 | Implemented |
BD0249 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $7,951 | $6,000 | Not Implemented |
BD0249 # 07 Y:2003 | 07 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $6,325 | $3,000 | Not Implemented |
BD0249 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,173 | $12,250 | Implemented |
BD0249 # 09 Y:2003 | 09 | 2003 | USE PHOTOCELL CONTROLS | $3,218 | $225 | Implemented |
BD0249 # 10 Y:2003 | 10 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,791 | $1,200 | Implemented |
BD0249 # 11 Y:2003 | 11 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,262 | $6,120 | Not Implemented |
BD0249 # 12 Y:2003 | 12 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,672 | $660 | Not Implemented |
BD0249 # 13 Y:2003 | 13 | 2003 | INSTALL OCCUPANCY SENSORS | $950 | $1,200 | Not Implemented |
BD0249 # 14 Y:2003 | 14 | 2003 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $885 | $200 | Not Implemented |
BD0249 # 15 Y:2003 | 15 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $755 | $0 | Not Implemented |
BD0249 # 16 Y:2003 | 16 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $575 | $24 | Not Implemented |
BD0249 # 17 Y:2003 | 17 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $294 | $335 | Implemented |
BD0249 # 18 Y:2003 | 18 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $274 | $500 | Not Implemented |
BD0249 # 19 Y:2003 | 19 | 2003 | TREAT AND REUSE RINSE WATERS | $29,980 | $10,000 | Not Implemented |
BD0249 # 20 Y:2003 | 20 | 2003 | MINIMIZE WATER USAGE | $11,992 | $0 | Implemented |
BD0249 # 21 Y:2003 | 21 | 2003 | INSTALL AUTOMATIC PACKING EQUIPMENT | $22,695 | $99,000 | Not Implemented |
BD0249 # 22 Y:2003 | 22 | 2003 | PAY BILLS ON TIME TO AVOID LATE FEES | $2,256 | $0 | Not Implemented |
BD0249 # 23 Y:2003 | 23 | 2003 | AUTOMATE PAYROLL SYSTEM | $1,639 | $2,500 | Implemented |
AS0367 # 01 Y:2004 | 01 | 2004 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $14,811 | $5,240 | Implemented |
AS0367 # 02 Y:2004 | 02 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $36,297 | $90,000 | Not Implemented |