Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,945
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0578 # 02 Y:1996 | 02 | 1996 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,045 | $1,000 | Implemented |
GT0578 # 03 Y:1996 | 03 | 1996 | INCREASE AMOUNT OF CONDENSATE RETURNED | $27,914 | $12,000 | Implemented |
GT0578 # 04 Y:1996 | 04 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,970 | $500 | Implemented |
GT0578 # 05 Y:1996 | 05 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $21,460 | $0 | Not Implemented |
GT0578 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,090 | $34,520 | Implemented |
GT0578 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $850 | $2,100 | Not Implemented |
OR0261 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,791 | $2,900 | Not Implemented |
OR0261 # 02 Y:1996 | 02 | 1996 | INSULATE FEEDWATER TANK | $1,450 | $2,383 | Implemented |
OR0261 # 03 Y:1996 | 03 | 1996 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,824 | $4,012 | Implemented |
OR0261 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,181 | $4,000 | Not Implemented |
OR0261 # 05 Y:1996 | 05 | 1996 | UTILIZE OXIDATION/REDUCTION FOR NEUTRALIZATION | $92,431 | $120,000 | Implemented |
BD0045 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,153 | $16,580 | Implemented |
BD0045 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,302 | $5,503 | Not Implemented |
BD0045 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $758 | $797 | Not Implemented |
BD0045 # 04 Y:1995 | 04 | 1995 | USE SYNTHETIC LUBRICANT | $667 | $480 | Not Implemented |
BD0045 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $314 | $375 | Not Implemented |
BD0045 # 06 Y:1995 | 06 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $259 | $100 | Not Implemented |
WI0246 # 01 Y:1995 | 01 | 1995 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,378 | $12,000 | Not Implemented |
WI0246 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,034 | $2,000 | Not Implemented |
WI0246 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,406 | $1,600 | Not Implemented |
WI0246 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,533 | $2,043 | Implemented |
WI0246 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $288 | $0 | Implemented |
WI0246 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,059 | $1,581 | Implemented |
WI0246 # 07 Y:1995 | 07 | 1995 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,406 | $10,000 | Not Implemented |
WI0246 # 08 Y:1995 | 08 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,210 | $5,800 | Implemented |