Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,945
matching recommendationsSIC | 203 | Preserved Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0450 # 09 Y:1995 | 09 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,319 | $0 | Not Implemented |
UD0450 # 01 Y:1995 | 01 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $9,163 | $0 | Implemented |
UD0450 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,096 | $2,000 | Implemented |
OK0457 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,236 | $13,720 | Not Implemented |
OK0457 # 02 Y:1995 | 02 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,691 | $64 | Implemented |
OK0457 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,741 | $4,508 | Implemented |
OK0457 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $1,344 | $3,612 | Implemented |
OK0457 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,224 | $2,077 | Implemented |
OK0457 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $882 | $2,480 | Not Implemented |
OK0457 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $199 | $240 | Implemented |
OK0457 # 08 Y:1995 | 08 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $49 | $76 | Implemented |
UL0115 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $472 | $1,520 | Not Implemented |
UL0115 # 02 Y:1994 | 02 | 1994 | COVER OPEN TANKS | $583 | $330 | Implemented |
UL0115 # 03 Y:1994 | 03 | 1994 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $4,013 | $4,000 | Implemented |
UL0115 # 04 Y:1994 | 04 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,505 | $2,000 | Not Implemented |
UL0115 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $132 | $346 | Implemented |
WI0224 # 01 Y:1994 | 01 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $12,194 | $20,000 | n/a |
WI0224 # 02 Y:1994 | 02 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,980 | $15,000 | n/a |
WI0224 # 03 Y:1994 | 03 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,846 | $500 | n/a |
WI0224 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,264 | $964 | n/a |
WI0224 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $272 | $0 | n/a |
WI0224 # 06 Y:1994 | 06 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $8,033 | $0 | n/a |
KG0010 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $23,359 | $48,100 | Implemented |
KG0010 # 02 Y:1994 | 02 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $21,337 | $1,260 | Not Implemented |
KG0010 # 03 Y:1994 | 03 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $7,603 | $1,050 | Implemented |