Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 2033 | Canned Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0193 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $159,261 | $64,000 | Not Implemented |
MI0193 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,000 | $1,210 | Implemented |
MI0193 # 02 Y:2010 | 02 | 2010 | HEAT WATER WITH EXHAUST HEAT | $100,762 | $23,000 | Implemented |
MI0193 # 07 Y:2010 | 07 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,182 | $1,750 | Implemented |
MI0193 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,565 | $4,531 | Not Implemented |
MI0193 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,004 | $40 | Implemented |
MI0193 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58,162 | $63,083 | Implemented |
MI0129 # 02 Y:2006 | 02 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,075 | $1,410 | Implemented |
MI0129 # 04 Y:2006 | 04 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $314 | $140 | Not Implemented |
MI0129 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,814 | $1,074 | Not Implemented |
MI0129 # 01 Y:2006 | 01 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,749 | $400 | Implemented |
MI0129 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $264 | $30 | Not Implemented |
UF0299 # 13 Y:2002 | 13 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,568 | $1,487 | Implemented |
UF0299 # 12 Y:2002 | 12 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $126,744 | $400,000 | Not Implemented |
UF0299 # 11 Y:2002 | 11 | 2002 | RECYCLE FLUORESCENT LAMPS | $63 | $0 | Implemented |
UF0299 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,494 | $0 | Implemented |
UF0299 # 07 Y:2002 | 07 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,545 | $120,962 | Not Implemented |
UF0299 # 08 Y:2002 | 08 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,543 | $0 | Implemented |
UF0299 # 10 Y:2002 | 10 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $30,592 | $15,000 | Not Implemented |
UF0299 # 02 Y:2002 | 02 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $5,901 | $1,000 | Not Implemented |
UF0299 # 09 Y:2002 | 09 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,134 | $0 | Implemented |
UF0299 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,988 | $5,732 | Implemented |
UF0299 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $45,724 | $81,293 | Implemented |
UF0299 # 04 Y:2002 | 04 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $65,908 | $37,050 | Implemented |
UF0299 # 03 Y:2002 | 03 | 2002 | USE PHOTOCELL CONTROLS | $13,442 | $36,067 | Not Implemented |