Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 2033 | Canned Fruits And Vegetables |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0138 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $320 | $0 | Implemented |
LT0138 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $336 | $154 | Not Implemented |
LT0138 # 04 Y:1988 | 04 | 1988 | INSTALL SET-BACK TIMERS | $150 | $206 | Implemented |
LT0138 # 01 Y:1988 | 01 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $648 | $1,801 | Not Implemented |
OR0019 # 02 Y:1988 | 02 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,700 | $300 | Implemented |
OR0019 # 09 Y:1988 | 09 | 1988 | OPTIMIZE PLANT POWER FACTOR | $2,952 | $6,720 | Not Implemented |
OR0019 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,690 | $2,604 | Implemented |
OR0019 # 07 Y:1988 | 07 | 1988 | INSULATE BARE EQUIPMENT | $7,722 | $7,598 | Implemented |
OR0019 # 06 Y:1988 | 06 | 1988 | INSULATE BARE EQUIPMENT | $13,283 | $5,026 | Implemented |
OR0019 # 05 Y:1988 | 05 | 1988 | INCREASE AMOUNT OF CONDENSATE RETURNED | $36,523 | $9,395 | Implemented |
OR0019 # 04 Y:1988 | 04 | 1988 | INSULATE BARE EQUIPMENT | $1,572 | $276 | Implemented |
OR0019 # 01 Y:1988 | 01 | 1988 | OPERATE BOILERS ON HIGH FIRE SETTING | $8,014 | $0 | Implemented |
OR0017 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $518 | $997 | Implemented |
OR0017 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $276 | $298 | Not Implemented |
OR0017 # 07 Y:1988 | 07 | 1988 | RECOVER AND REUSE COOLING WATER | $502 | $320 | Not Implemented |
OR0017 # 06 Y:1988 | 06 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $150 | $76 | Not Implemented |
OR0017 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,466 | $300 | Implemented |
OR0017 # 04 Y:1988 | 04 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,291 | $0 | Implemented |
OR0017 # 03 Y:1988 | 03 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,710 | $0 | Implemented |
OR0017 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $818 | $0 | Not Implemented |
OR0017 # 01 Y:1988 | 01 | 1988 | USE MINIMUM STEAM OPERATING PRESSURE | $326 | $0 | Implemented |
TN0332 # 01 Y:1988 | 01 | 1988 | USE MINIMUM STEAM OPERATING PRESSURE | $13,494 | $0 | Not Implemented |
TN0332 # 02 Y:1988 | 02 | 1988 | CLOSE OFF UNNEEDED STEAM LINES | $9,055 | $0 | Not Implemented |
TN0332 # 03 Y:1988 | 03 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,426 | $4,205 | Not Implemented |
TN0332 # 04 Y:1988 | 04 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,369 | $1,850 | Not Implemented |