Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 2035 | Pickles, Sauces, And Salad Dressings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0064 # 08 Y:1989 | 08 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $364 | $800 | Not Implemented |
WI0064 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $533 | $500 | Not Implemented |
WI0064 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $304 | $419 | Implemented |
WI0064 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $803 | $5,000 | Not Implemented |
WI0064 # 04 Y:1989 | 04 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $13,766 | $0 | Implemented |
WI0064 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,709 | $0 | Not Implemented |
WI0064 # 02 Y:1989 | 02 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $16,875 | $1,500 | Not Implemented |
WI0064 # 01 Y:1989 | 01 | 1989 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $98,647 | $400,000 | Not Implemented |
OR0051 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $444 | $500 | Implemented |
OR0051 # 08 Y:1989 | 08 | 1989 | OPTIMIZE PLANT POWER FACTOR | $2,544 | $5,400 | Not Implemented |
OR0051 # 07 Y:1989 | 07 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,450 | $8,000 | Not Implemented |
OR0051 # 06 Y:1989 | 06 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $467 | $503 | Implemented |
OR0051 # 04 Y:1989 | 04 | 1989 | INSTALL STEAM TRAP | $23,375 | $2,335 | Implemented |
OR0051 # 03 Y:1989 | 03 | 1989 | USE MINIMUM STEAM OPERATING PRESSURE | $458 | $0 | Implemented |
OR0051 # 02 Y:1989 | 02 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,926 | $0 | Implemented |
OR0051 # 01 Y:1989 | 01 | 1989 | INSTALL SET-BACK TIMERS | $14,990 | $0 | Implemented |
OR0048 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $519 | $500 | Not Implemented |
OR0048 # 07 Y:1989 | 07 | 1989 | OPTIMIZE PLANT POWER FACTOR | $592 | $1,500 | Implemented |
OR0048 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,327 | $13,600 | Not Implemented |
OR0048 # 05 Y:1989 | 05 | 1989 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,545 | $7,500 | Implemented |
OR0048 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $135 | $138 | Not Implemented |
OR0048 # 03 Y:1989 | 03 | 1989 | RECOVER AND REUSE COOLING WATER | $473 | $402 | Implemented |
OR0048 # 02 Y:1989 | 02 | 1989 | RECOVER AND REUSE COOLING WATER | $622 | $316 | Implemented |