Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,021

matching recommendations
Reset
SIC 204 Grain Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0127 # 06 Y:1984 06 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,298 $0 Implemented
KU0127 # 10 Y:1984 10 1984 INSULATE BARE EQUIPMENT $1,267 $1,700 Implemented
KU0127 # 11 Y:1984 11 1984 INSTALL TIMERS AND/OR THERMOSTATS $1,116 $300 Implemented
KU0127 # 12 Y:1984 12 1984 REPAIR AND ELIMINATE STEAM LEAKS $187 $60 Implemented
TN0206 # 01 Y:1984 01 1984 REPAIR AND ELIMINATE STEAM LEAKS $24,831 $580 Implemented
TN0206 # 02 Y:1984 02 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $12,768 $1,266 Implemented
TN0206 # 03 Y:1984 03 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,502 $300 Implemented
TN0206 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,379 $3,148 Implemented
OK0119 # 01 Y:1984 01 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $45 $500 Implemented
OK0119 # 02 Y:1984 02 1984 INSTALL TIMERS AND/OR THERMOSTATS $216 $0 Implemented
OK0119 # 03 Y:1984 03 1984 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $375 $0 Implemented
TN0190 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,800 $300 Implemented
TN0190 # 02 Y:1983 02 1983 INSTALL SET-BACK TIMERS $1,000 $0 Implemented
TN0190 # 03 Y:1983 03 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $60 $0 Implemented
KU0056 # 01 Y:1982 01 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,692 $2,784 Implemented
KU0056 # 02 Y:1982 02 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $17,863 $2,000 Implemented
KU0056 # 03 Y:1982 03 1982 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $16,065 $20,000 Implemented
KU0056 # 05 Y:1982 05 1982 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $10,800 $20,000 Implemented
KU0056 # 06 Y:1982 06 1982 INSTALL / REPAIR INSULATION ON STEAM LINES $5,190 $1,724 Implemented
KU0056 # 07 Y:1982 07 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,225 $1,000 Implemented
KU0056 # 08 Y:1982 08 1982 RECOVER WASTE HEAT FROM EQUIPMENT $3,030 $2,940 Implemented