Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,103

matching recommendations
Reset
SIC 204 Grain Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0088 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $669 $1,148 Implemented
NV0088 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $2,073 $900 Implemented
NV0088 # 06 Y:1997 06 1997 INSULATE BARE EQUIPMENT $163 $86 Implemented
NV0088 # 07 Y:1997 07 1997 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $5,400 $1,410 Implemented
NV0088 # 08 Y:1997 08 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $4,800 $500 Implemented
NV0088 # 09 Y:1997 09 1997 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $23,140 $17,160 Implemented
NV0088 # 10 Y:1997 10 1997 CLEAR AND RENT EXISTING SPACE $3,485 $4,950 Implemented
IA0178 # 01 Y:1997 01 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,051 $1,100 Implemented
IA0178 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,223 $1,915 Implemented
IA0178 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $538 $50 Implemented
IA0178 # 04 Y:1997 04 1997 INSTALL OCCUPANCY SENSORS $166 $630 Not Implemented
IA0178 # 05 Y:1997 05 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $2,100 $8,100 Implemented
IA0178 # 06 Y:1997 06 1997 RECOVER AND REUSE COOLING WATER $3,700 $5,453 Implemented
IA0178 # 07 Y:1997 07 1997 IMPROVE HANDLING PRACTICES $91,000 $4,500 Implemented
UM0097 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,449 $4,445 Implemented
UM0097 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,340 $1,500 Implemented
UM0097 # 03 Y:1997 03 1997 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,254 $2,400 Not Implemented
UM0097 # 04 Y:1997 04 1997 MINIMIZE WATER USAGE $915 $0 Not Implemented
UM0097 # 05 Y:1997 05 1997 INSTALL AUTOMATIC PACKING EQUIPMENT $187,572 $28,169 Implemented
OR0297 # 01 Y:1997 01 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $3,530 $0 Not Implemented
OR0297 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,121 $3,853 Not Implemented
OR0297 # 03 Y:1997 03 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,160 $500 Not Implemented
OR0297 # 04 Y:1997 04 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $171 $0 Not Implemented
OR0297 # 05 Y:1997 05 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $2,706 $8,250 Not Implemented
OR0297 # 06 Y:1997 06 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $2,420 $130 Not Implemented