Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 204 | Grain Mill Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0069 # 02 Y:1993 | 02 | 1993 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $62,688 | $80,010 | Not Implemented |
IA0069 # 03 Y:1993 | 03 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,911 | $2,500 | Implemented |
IA0069 # 04 Y:1993 | 04 | 1993 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,716 | $1,040 | Implemented |
IA0069 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $637 | $1,700 | Not Implemented |
IA0069 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $720 | $0 | Implemented |
IA0069 # 01 Y:1993 | 01 | 1993 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $363,236 | $1,064,000 | Not Implemented |
SD0064 # 13 Y:1993 | 13 | 1993 | INSTALL SET-BACK TIMERS | $174 | $100 | Implemented |
SD0064 # 12 Y:1993 | 12 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,459 | $120 | Implemented |
SD0064 # 11 Y:1993 | 11 | 1993 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,874 | $1,256 | Implemented |
SD0064 # 10 Y:1993 | 10 | 1993 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $12,485 | $15,690 | Implemented |
SD0064 # 09 Y:1993 | 09 | 1993 | USE OPTIMUM THICKNESS INSULATION | $255 | $228 | Not Implemented |
SD0064 # 08 Y:1993 | 08 | 1993 | USE OPTIMUM THICKNESS INSULATION | $193 | $61 | Not Implemented |
SD0064 # 07 Y:1993 | 07 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $216 | $412 | Not Implemented |
SD0064 # 06 Y:1993 | 06 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,928 | $674 | Implemented |
SD0064 # 05 Y:1993 | 05 | 1993 | KEEP BOILER TUBES CLEAN | $4,163 | $2,000 | Implemented |
SD0064 # 04 Y:1993 | 04 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $795 | $600 | Implemented |
SD0064 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,125 | $60 | Not Implemented |
SD0064 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,679 | $5,291 | Implemented |
SD0064 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $907 | $1,038 | Implemented |
SD0064 # 14 Y:1993 | 14 | 1993 | USE PHOTOCELL CONTROLS | $1,543 | $575 | Implemented |
SD0064 # 15 Y:1993 | 15 | 1993 | INSTALL SET-BACK TIMERS | $400 | $760 | Implemented |
SD0064 # 17 Y:1993 | 17 | 1993 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $110 | $174 | Not Implemented |
SD0064 # 16 Y:1993 | 16 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $293 | $24 | Implemented |
ND0166 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $180 | $200 | Not Implemented |
ND0166 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $651 | $125 | Implemented |