Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
305
matching recommendationsSIC | 2047 | Dog And Cat Food |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0445 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $585 | $1,485 | Not Implemented |
OK0445 # 04 Y:1994 | 04 | 1994 | USE PHOTOCELL CONTROLS | $90 | $75 | Implemented |
OK0445 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,491 | $3,107 | Not Implemented |
OK0445 # 06 Y:1994 | 06 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $795 | $229 | Not Implemented |
OK0445 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,303 | $17,600 | Implemented |
OK0445 # 08 Y:1994 | 08 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,445 | $0 | Implemented |
OK0445 # 09 Y:1994 | 09 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $739 | $2,618 | Implemented |
IA0069 # 01 Y:1993 | 01 | 1993 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $363,236 | $1,064,000 | Not Implemented |
IA0069 # 02 Y:1993 | 02 | 1993 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $62,688 | $80,010 | Not Implemented |
IA0069 # 03 Y:1993 | 03 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,911 | $2,500 | Implemented |
IA0069 # 04 Y:1993 | 04 | 1993 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,716 | $1,040 | Implemented |
IA0069 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $637 | $1,700 | Not Implemented |
IA0069 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $720 | $0 | Implemented |
IA0038 # 01 Y:1992 | 01 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,039 | $9,600 | Not Implemented |
IA0038 # 02 Y:1992 | 02 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,673 | $2,484 | Not Implemented |
IA0038 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,907 | $150 | Implemented |
IA0038 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $848 | $25 | Not Implemented |
IA0038 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $693 | $1,875 | Not Implemented |
IA0038 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $1,925 | $1,926 | Not Implemented |
ND0001 # 01 Y:1991 | 01 | 1991 | OPTIMIZE PLANT POWER FACTOR | $17,472 | $19,313 | Implemented |
ND0001 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $840 | $1,000 | Implemented |
ND0001 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $107 | $400 | Implemented |
ND0001 # 04 Y:1991 | 04 | 1991 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $240 | $200 | Implemented |
ND0001 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $527 | $2,287 | Implemented |
ND0001 # 06 Y:1991 | 06 | 1991 | DISCONNECT BALLASTS | $60 | $200 | Implemented |