Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

877

matching recommendations
Reset
SIC 2048 Prepared Feeds, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0222 # 08 Y:2005 08 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $521 $206 Implemented
SU0222 # 09 Y:2005 09 2005 KEEP BOILER TUBES CLEAN $1,689 $800 Not Implemented
SU0222 # 10 Y:2005 10 2005 INSTALL OCCUPANCY SENSORS $211 $127 Implemented
SU0222 # 11 Y:2005 11 2005 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $1,287 $895 Implemented
SU0222 # 12 Y:2005 12 2005 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $200 $342 Implemented
SU0222 # 13 Y:2005 13 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $155 $292 Implemented
AM0471 # 01 Y:2004 01 2004 REPAIR OR REPLACE STEAM TRAPS $7,600 $930 Implemented
AM0471 # 02 Y:2004 02 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $6,640 $4,600 Implemented
AM0471 # 03 Y:2004 03 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $6,020 $270 Implemented
AM0471 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,450 $400 Implemented
AM0471 # 05 Y:2004 05 2004 USE SYNTHETIC LUBRICANT $1,920 $0 Implemented
AM0471 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $1,110 $170 Implemented
AM0471 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $230 $630 Implemented
CO0545 # 01 Y:2004 01 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $8,950 $1,500 Implemented
CO0545 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $5,800 $1,760 Implemented
CO0545 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $355 $800 Implemented
CO0545 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,170 $420 Implemented
CO0545 # 05 Y:2004 05 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $5,290 $250 Not Implemented
BD0256 # 01 Y:2004 01 2004 RECOVER WASTE HEAT FROM EQUIPMENT $146,428 $60,000 Implemented
BD0256 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $62,641 $14,500 Implemented
BD0256 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,608 $0 Implemented
BD0256 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,310 $645 Not Implemented
BD0256 # 05 Y:2004 05 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,326 $16,700 Not Implemented
BD0256 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,554 $1,845 Implemented
BD0256 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,832 $9,540 Not Implemented