Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

82

matching recommendations
Reset
SIC 2048 Prepared Feeds, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0140 # 04 Y:1996 04 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $762 $750 Implemented
SD0140 # 05 Y:1996 05 1996 REUSE / RECYCLE/ SELL PAPER PRODUCTS $15,120 $3,000 Implemented
SD0140 # 06 Y:1996 06 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $12,600 $11,000 Implemented
SD0072 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,515 $2,413 Implemented
SD0072 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,016 $13,590 Implemented
SD0072 # 03 Y:1994 03 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $320 $95 Implemented
SD0072 # 07 Y:1994 07 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,238 $300 Implemented
SD0072 # 09 Y:1994 09 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $2,104 $2,070 Implemented
SD0072 # 10 Y:1994 10 1994 USE PHOTOCELL CONTROLS $619 $115 Implemented
SD0072 # 11 Y:1994 11 1994 INSTALL OCCUPANCY SENSORS $1,245 $760 Implemented
SD0072 # 12 Y:1994 12 1994 USE POWER DURING OFF-PEAK PERIODS $10,026 $0 Implemented
SD0072 # 06 Y:1994 06 1994 INSULATE FEEDWATER TANK $243 $309 Implemented
SD0072 # 05 Y:1994 05 1994 REPAIR AND ELIMINATE STEAM LEAKS $1,623 $225 Implemented
SD0072 # 04 Y:1994 04 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,579 $3,227 Not Implemented
SD0072 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $912 $60 Implemented
SD0064 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $907 $1,038 Implemented
SD0064 # 17 Y:1993 17 1993 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $110 $174 Not Implemented
SD0064 # 16 Y:1993 16 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $293 $24 Implemented
SD0064 # 15 Y:1993 15 1993 INSTALL SET-BACK TIMERS $400 $760 Implemented
SD0064 # 14 Y:1993 14 1993 USE PHOTOCELL CONTROLS $1,543 $575 Implemented
SD0064 # 13 Y:1993 13 1993 INSTALL SET-BACK TIMERS $174 $100 Implemented
SD0064 # 12 Y:1993 12 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,459 $120 Implemented
SD0064 # 11 Y:1993 11 1993 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,874 $1,256 Implemented
SD0064 # 10 Y:1993 10 1993 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,485 $15,690 Implemented
SD0064 # 02 Y:1993 02 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,679 $5,291 Implemented