Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
106
matching recommendationsSIC | 205 | Bakery Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0373 # 02 Y:1989 | 02 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $7,050 | $11,350 | Implemented |
TN0373 # 03 Y:1989 | 03 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $8,465 | $12,145 | Not Implemented |
TN0373 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,164 | $180 | Implemented |
TN0373 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $46 | $0 | Implemented |
TN0373 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,599 | $1,800 | Implemented |
TN0373 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,407 | $540 | Implemented |
TN0307 # 01 Y:1987 | 01 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,272 | $53,800 | Not Implemented |
TN0307 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,495 | $0 | Implemented |
TN0307 # 03 Y:1987 | 03 | 1987 | USE OPTIMUM THICKNESS INSULATION | $2,858 | $2,841 | Implemented |
TN0307 # 04 Y:1987 | 04 | 1987 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $8,300 | $1,860 | Implemented |
TN0307 # 05 Y:1987 | 05 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $2,457 | $3,100 | Implemented |
TN0307 # 06 Y:1987 | 06 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,211 | $176 | Implemented |
TN0307 # 07 Y:1987 | 07 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,505 | $0 | Implemented |
TN0307 # 08 Y:1987 | 08 | 1987 | INSULATE BARE EQUIPMENT | $144 | $66 | Implemented |
TN0284 # 01 Y:1986 | 01 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,573 | $1,383 | Implemented |
TN0284 # 02 Y:1986 | 02 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $8,026 | $14,300 | Implemented |
TN0284 # 03 Y:1986 | 03 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,112 | $195 | Implemented |
TN0284 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $707 | $104 | Implemented |
TN0284 # 05 Y:1986 | 05 | 1986 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $422 | $800 | Implemented |
TN0284 # 06 Y:1986 | 06 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $80 | $300 | Implemented |
TN0276 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $4,831 | $95 | Implemented |
TN0276 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,382 | $0 | Implemented |
TN0276 # 03 Y:1986 | 03 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,515 | $5,000 | Not Implemented |
TN0276 # 04 Y:1986 | 04 | 1986 | INSULATE BARE EQUIPMENT | $566 | $1,851 | Implemented |
TN0276 # 05 Y:1986 | 05 | 1986 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $746 | $3,600 | Not Implemented |