Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20

matching recommendations
Reset
SIC 2052 Cookies And Crackers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1505 # 02 Y:2015 02 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,107 $266 Implemented
UK1505 # 11 Y:2015 11 2015 REPAIR AND ELIMINATE STEAM LEAKS $2,571 $5,110 Implemented
UK1505 # 10 Y:2015 10 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $548 $276 Implemented
UK1505 # 09 Y:2015 09 2015 INSTALL / REPAIR INSULATION ON STEAM LINES $3,562 $3,824 Implemented
UK1505 # 08 Y:2015 08 2015 PREHEAT COMBUSTION AIR WITH WASTE HEAT $54,447 $42,474 Not Implemented
UK1505 # 07 Y:2015 07 2015 INSTALL OCCUPANCY SENSORS $296 $61 Implemented
UK1505 # 06 Y:2015 06 2015 USE ONLY CERTIFIED MOTOR REPAIR SHOPS $1,747 $635 Implemented
UK1505 # 05 Y:2015 05 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,998 $0 Implemented
UK1505 # 04 Y:2015 04 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,753 $3,800 Implemented
UK1505 # 03 Y:2015 03 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,528 $4,500 Implemented
UK1505 # 01 Y:2015 01 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,028 $1,750 Implemented
BD0464 # 01 Y:2015 01 2015 PREHEAT COMBUSTION AIR WITH WASTE HEAT $12,126 $18,000 Not Implemented
BD0464 # 09 Y:2015 09 2015 SHUT OFF PILOTS IN STANDBY EQUIPMENT $590 $40 Implemented
BD0464 # 08 Y:2015 08 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $996 $700 Not Implemented
BD0464 # 07 Y:2015 07 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,313 $750 Implemented
BD0464 # 06 Y:2015 06 2015 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,364 $2,900 Implemented
BD0464 # 05 Y:2015 05 2015 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,866 $20 Not Implemented
BD0464 # 04 Y:2015 04 2015 INSTALL OCCUPANCY SENSORS $6,685 $3,075 Implemented
BD0464 # 03 Y:2015 03 2015 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,022 $30,000 Not Implemented
BD0464 # 02 Y:2015 02 2015 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $11,746 $20,000 Implemented