IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

998

matching recommendations
Reset
SIC 206 Sugar And Confectionery Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0055 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,476 $8,464 Implemented
WI0055 # 05 Y:1989 05 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,852 $7,000 Implemented
WI0055 # 06 Y:1989 06 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,976 $0 Implemented
WI0055 # 07 Y:1989 07 1989 INSTALL STORM WINDOWS AND DOORS $1,472 $2,444 Implemented
WI0055 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,325 $0 Implemented
WI0055 # 09 Y:1989 09 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,028 $3,000 Not Implemented
CO0143 # 01 Y:1989 01 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32,873 $4,000 Implemented
CO0143 # 02 Y:1989 02 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $7,709 $3,000 Not Implemented
CO0143 # 03 Y:1989 03 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,778 $1,200 Implemented
CO0143 # 04 Y:1989 04 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $9,866 $15,850 Implemented
CO0143 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,427 $1,373 Implemented
CO0143 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28 $92 Implemented
GT0369 # 01 Y:1989 01 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $184 $108 Implemented
GT0369 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $943 $580 Not Implemented
GT0369 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $498 $765 Implemented
GT0369 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $1,950 $2,670 Not Implemented
GT0369 # 05 Y:1989 05 1989 INSTALL SET-BACK TIMERS $165 $280 Not Implemented
CO0115 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,100 $7,000 Implemented
CO0115 # 02 Y:1988 02 1988 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $112,791 $80,000 Not Implemented
CO0115 # 03 Y:1988 03 1988 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $23,377 $5,000 Implemented
CO0115 # 04 Y:1988 04 1988 REDUCE EXCESS STEAM BLEEDING $3,914 $2,000 Implemented
CO0115 # 05 Y:1988 05 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $4,410 $10,670 Implemented
CO0115 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,111 $0 Implemented
CO0115 # 07 Y:1988 07 1988 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,557 $38,200 Implemented
CO0116 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $151,329 $7,000 Implemented