Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 206 | Sugar And Confectionery Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0444 # 08 Y:2012 | 08 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,828 | $32,000 | Not Implemented |
NC0444 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,193 | $53,707 | Not Implemented |
NC0444 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,844 | $62,067 | Not Implemented |
NC0444 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,178 | $971 | Implemented |
NC0444 # 04 Y:2012 | 04 | 2012 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $2,902 | $4,000 | Implemented |
NC0444 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,731 | $500 | Implemented |
NC0444 # 02 Y:2012 | 02 | 2012 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $3,445 | $8,500 | Not Implemented |
NC0444 # 01 Y:2012 | 01 | 2012 | ADJUST BURNERS FOR EFFICIENT OPERATION | $5,257 | $2,000 | Implemented |
NC0260 # 06 Y:2003 | 06 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $234 | $0 | Not Implemented |
NC0260 # 09 Y:2003 | 09 | 2003 | USE PHOTOCELL CONTROLS | $806 | $550 | Not Implemented |
NC0260 # 08 Y:2003 | 08 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $264 | $252 | Not Implemented |
NC0260 # 07 Y:2003 | 07 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $347 | $260 | Not Implemented |
NC0260 # 05 Y:2003 | 05 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,263 | $16,548 | Not Implemented |
NC0260 # 04 Y:2003 | 04 | 2003 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $606 | $176 | Not Implemented |
NC0260 # 03 Y:2003 | 03 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $16,074 | $9,000 | Not Implemented |
NC0260 # 02 Y:2003 | 02 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $19,437 | $8,000 | Not Implemented |
NC0260 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $396 | $208 | Not Implemented |
TN0574 # 01 Y:1996 | 01 | 1996 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $115,000 | $140,000 | Not Implemented |
TN0574 # 07 Y:1996 | 07 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $500 | $300 | Implemented |
TN0574 # 06 Y:1996 | 06 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,000 | $0 | Implemented |
TN0574 # 05 Y:1996 | 05 | 1996 | ELIMINATE/REDUCE AN OPERATION | $5,000 | $9,000 | Not Implemented |
TN0574 # 04 Y:1996 | 04 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $7,000 | $0 | Not Implemented |
TN0574 # 03 Y:1996 | 03 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,000 | $600 | Not Implemented |
TN0574 # 02 Y:1996 | 02 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $79,000 | $22,000 | Implemented |