Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 206 | Sugar And Confectionery Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0191 # 02 Y:2011 | 02 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,804 | $57,885 | n/a |
IC0191 # 03 Y:2011 | 03 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,379 | $0 | n/a |
IC0191 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $6,711 | $2,345 | n/a |
IC0191 # 05 Y:2011 | 05 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $190 | $150 | n/a |
IC0191 # 06 Y:2011 | 06 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $714 | $200 | n/a |
IC0191 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $893 | $0 | n/a |
IC0191 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,189 | $690 | n/a |
IC0191 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,161 | $109,685 | n/a |
OK0804 # 14 Y:2011 | 14 | 2011 | OPTIMIZE PLANT POWER FACTOR | $2,073 | $8,279 | Not Implemented |
OK0804 # 13 Y:2011 | 13 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,107 | $19,271 | Not Implemented |
OK0804 # 12 Y:2011 | 12 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $807 | $1,843 | Not Implemented |
OK0804 # 11 Y:2011 | 11 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,295 | $2,286 | Not Implemented |
OK0804 # 10 Y:2011 | 10 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,632 | $4,325 | Not Implemented |
OK0804 # 09 Y:2011 | 09 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,362 | $750 | Implemented |
OK0804 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,244 | $4,120 | Not Implemented |
OK0804 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,223 | $18,797 | Not Implemented |
OK0804 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,996 | $28,404 | Not Implemented |
OK0804 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,796 | $56,474 | Implemented |
OK0804 # 04 Y:2011 | 04 | 2011 | INSTALL SET-BACK TIMERS | $740 | $1,625 | Not Implemented |
OK0804 # 03 Y:2011 | 03 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $12,835 | $19,625 | Not Implemented |
OK0804 # 02 Y:2011 | 02 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $64,961 | $238,050 | Not Implemented |
OK0804 # 01 Y:2011 | 01 | 2011 | Install Anaerobic Digester | $544,130 | $5,652,880 | Not Implemented |